DMMetering PRO-1250 Series Manual Download Page 3

®

   

2007

 

 

Installation, maintenance and reparation should only be done by qualified 
personnel. 

 

Never break the seals and open the front cover as this might influence the 
functionality of the meter, and will avoid any warranty. 

 

Do not drop, or allow physical impact to the meter as there are high precision 
components inside that may break. 

 
 

Exclusion of liability 

We have checked the contents of this publication and every effort has been made to 
ensure that the descriptions are as accurate as possible. 
However, deviations from the description cannot be completely ruled out, so that no 
liability can be accepted for any errors contained in the information given. The data 
in this manual is checked regularly and the necessary corrections are included in 
subsequent editions. We are grateful for any improvements that you care to 
suggest. 
 

Subject to technical modifications without notice.

 

 
 

Copyright 

 

Copyright DMMetering November 2007 All rights Reserved. 
It is prohibited to pass on or copy this document or to use or disclose its contents 
without our express permission. Any duplication is a violation of the law and subject 
to criminal and civil penalties. All rights reserved, particularly in the event of a 
patent award or utility model registration. 

 

 

Registered trademarks

 

DMMetering

®

  is  registered  trademark  of  Inepro  Industries  Ltd  –  member  of  the 

Inepro Group. The other names appearing in this manual may be trade names the 
use of these names by third parties for their own purposes may infringe the rights 
of the owners. 

 
1.2    Foreword 

 

Thank you for purchasing the DMMetering PRO1250 SERIES DIN rail three phase 
four wire energy meter. The DMMetering PRO1250 SERIES energy meter is the 
most advanced type electronic kWh meter available at the market. With the 
DMMetering product range we have introduced a large scale of energy meters on 
the market suitable for 110V AC to 400V AC (50 or 60Hz). Besides the normal 
energy meters we also developed our own pre-paid meters with chip card, chip card 
re-loaders and a complete PC management control system. For more information 
on other product please contact our sales department at [email protected] or 
[email protected]
 
Although we produce the DMMetering PRO1250 SERIES meter according to IEC 
62053-21 and our quality inspection is very accurate there might always be a 
possibility that your product shows a fault or failure for which we do apologize. 
Under normal conditions your product should give you years of benefit and pleasure. 
In case there is a problem with the energy meter you should contact your dealer 
immediately. All energy meters are sealed with a special seal. Once this seal is 
broken there is no possibility to claim for warranty. Therefore NEVER open an 
energy meter or break the seal of the energy meter. The warranty time is 5 years, 
after production, and only valid for construction faults. 

Summary of Contents for PRO-1250 Series

Page 1: ...se four wire energy meter 1 1 Safety instruction 1 2 Foreword 1 3 Performance criteria 1 4 Specifications 1 5 Basic errors 1 6 Description 1 7 Dimensions 1 8 Installation 1 9 Operating 1 10 Troublesho...

Page 2: ...ground and label devices systems and circuits according to safety and Regulatory standards Use for the intended purpose The equipment device module may only be used for the application cases specified...

Page 3: ...member of the Inepro Group The other names appearing in this manual may be trade names the use of these names by third parties for their own purposes may infringe the rights of the owners 1 2 Forewor...

Page 4: ...d 6KV 1 2 S waveform Basic current Ib CT version 1A Direct version 10A Maximum rated current Imax CT version 5A Direct version 100A Operational current range 0 4 Ib Imax Over current withstand 30Imax...

Page 5: ...ription A Front panel B Cover C Base D Security hasp Material Front panel PC inflammable retarding Cover ABS inflammable retarding Base ABS inflammable retarding 1 7 Dimensions Height 130 mm Width 126...

Page 6: ...meter has to be installed in a protection box when placed in dangerous or dusty environment The meter can be installed and used after being tested and sealed with a letter press printing The meter ca...

Page 7: ...color and one decimal is marked with red The PRO 1250D series energy meter is equipped with 5 2 LCD display which is used as recording consumption and can t be reset to zero The reading accuracy is 1...

Page 8: ...ank wire or other material as you will have the chance of an electricity shock and a possible chance for health damage Turn off and lock out all power supplying the energy meter and the equipment to w...

Page 9: ...or L2 or L3 when power supply is input Reinstall terminal screws on the 1 2 3 4 5 6 and 7 Make sure all screws are fixed Than there should be a 230V 50Hz AC voltage between the terminal screws on the...

Page 10: ...is is why it seems like the meter won t count Please contact your technical supporter to replace this meter No test pulse output Is DC power supply connected to the meter Is the connecting correct May...

Reviews: