Step 4. Commutation phase adjustment
*This step applicable only to models with commutation output.
For motor applications only.
Power up the encoder with supply voltage.
The commutation phase reference mechanical location is adjusted
using the on-board potentiometer. The mechanical phase angle
can be adjusted up to 180°.
Externally actuate the motor shaft so the motor generates back-EMF,
and the encoder rotary is also rotated. Synchronize the motor back-EMF
voltage with the encoder output U + signal (or V + or W +) by
adjusting the on-board potentiometer.
Rotate the potentiometer while viewing the U + signal and motor
back-EMF voltage to zero synchronize the commutation signal.
Once the motor back-EMF and encoder commutation are matched,
the U,V,W commutation adjustment process is complete.
Ensure the potentiometer dial cannot be unexpectedly moved
during normal operation.
Interface
□
A leads B for CCW rotation - viewed from encoder shaft/mounting side
□
Line Driver Output
□
14-position, 0.4mm O.D. copper conductor
□
6mm O.D. interface cable
□
Max. Cable Distance = 100m
PRODUCT TERMS
All specified data subject to change without notice to reflect updates and improvements made to product. DMM Technology Corp. warrants the quality and performance of for one year
starting date of shipment from original factory. DMM Technology Corp. assumes no responsibility for damages resulting from user related errors or improper use of product, in which
case the warranty terms will be void. Safety precautions should be considered for all applications. As this product does not include safety conditions, always design a higher level
feedback to reduce the risks of product or bodily harm. All information included in this manual represents data measured under DMM Technology Corp’s own test conditions. Actual
performance may vary and the user is responsible for optimizing the application with respect to the encoder’s capabilities.
DMM Technology Corp. ©2013
Installation Manual
DMMDSN05_INMT | rev. A1.4 | 09/13
DMM Technology Corp.
3125 - 21331 Gordon Way
Richmond, BC V6W 1J9
Canada
TEL : +1.604.370.4168
MAIL : [email protected] | [email protected]
WEB : www.dmm-tech.com
www.dmm-tech.com
03-03
Potentiometer Adjustment
Mis-aligned
Aligned
Tuning complete!
Encoder U phase
Motor back E.M.F
Measured between U,V
motor power wires