![DMG Amigo II ETSA2MRA Installation Manual Download Page 22](http://html1.mh-extra.com/html/dmg/amigo-ii-etsa2mra/amigo-ii-etsa2mra_installation-manual_2513731022.webp)
Audio Messages playback (§ 3.2.21)
22
DESCRIPTION / PARAMETER
CODE
DTMF VALUES
00
01
02
03
04
05
06
07
16
17
123456789
(default)
123456789
(default)
None
(default)
None
(default)
None
(default)
None
(default)
123456789
(default)
0
= NO contact (default) /
1
= NC contact
1st number
2nd number
3rd number
4th number
5th number
6th number
None
(default)
16 digits maximum
16 digits maximum
16 digits maximum
Recording of phone numbers
(max.6) to be called during the
alarm cycle
Recording of the service call number for service
messages
Setting of max. conversation time (3÷9 min.)
Recording of unique
ID number
(supplied by the call
center) to be sent out in case of alarm
Type of contact (NO/NC) setting on the alarm button
connected to ETSA2MRA
Remote parameters' setting table
08
Setting of communication protocol
0
= None (default) /
1
= Anep /
2
= Ademco /
3
= P100
4
= DMG 4 Digits /
5
= DMG 10 Digits
09
1
= 1 time /
2
= 2 times /
3
= 3 times (default) / ............... /
9
= 9 times
Setting of max. number (1÷9) of attempts for the alarm
cycle to before the system returns to stand-by mode
10
12
0
= 0 sec. (default) /
1
= 1 sec. /
2
= 2 sec. /
3
= 3 sec. /
4
= 4 sec. /
5
= 5 sec.
Setting of the minimum time (0÷5 sec.) for the alarm
button to be pressed before the alarm cycle is
triggered
Set the periodic test call intervall
(EN_81-28)
Manual test time
11
13
0
= NO Reset /
1
= Reset
Reset to default config.
Language choice
14
15
Password
18
19
Rings before answer (§ 3.2.19)
1 ÷ 9
Rings
0
= OFF /
1
= ON /
2
= Playback CAR Only
20
Remote alarm reset
0
= Reset
1
= Français /
2
= Deutsch /
3
= Italiano (default)
4
= Russkiy /
5
= English /
6
= Portugues
Automatic call closed recognition
(§ 3.2.18)
21
0
= Disabled /
1
= Enabled
Call center reply timeout
(§ 3.2.20)
22
1
= 10 seconds ...
9
= 90 seconds
Automatic Identity Message
(§ 3.2.14)
23
0
= Disabled /
1
= Enabled
Unit ID in multiline configuration
(§ 3.2.23)
24
0
= Disabled /
1
= Master /
2
= 2 ...
9
= 9
Double Language Messages
(§ 3.2.22)
25
0
= Disabled /
1
= Français /
2
= Deutsch /
3
= Italiano (default)
4
= Russkiy /
5
= English /
6
= Portugues
3
= 3 min. (default) /
4
= 4 min. /
5
= 5 min. / ............... /
9
= 9 min.
1
= 20 sec. (default) /
2
= 25 sec. /
3
= 30 sec.
Power supply test
(§ 3.2.24)
26
0
= CH2 /
1
= CH3
1
= 24h /
2
= 48h /
3
= 72h (default)
Summary of Contents for Amigo II ETSA2MRA