Manual cable marking: pre-termination 

161

 C

TT C

rimping solutions

AMP

DMC AF8 adjustable crimp tool 

AF8 tool

Part number

Military part 

number

Description

AF8

M22520/1-01

Tool frame

TH1A

M22520/1-02

Turret

TH4

M22520/1-03

Turret

TH163

M22520/1-04

Adjustable 

positioner

UH2-5

M22520/1-05

Positioner

TP45

M22520/1-06

Positioner

TP85

M22520/1-07

Positioner

TH199S

M22520/1-08

Positioner

TP360

M22520/1-09

Positioner

TP365

M22520/1-10

Positioner

TP465

M22520/1-11

Positioner

TH270

M22520/1-12

Positioner

TH285

M22520/1-13

Positioner

TH286

M22520/1-14

Positioner

TP485

M22520/1-15

Positioner

TP513

M22520/1-16

Positioner

TP651

M22520/1-17

Positioner

G125

M22520/3-1

Gage

AF8 standard adjustable crimp tool 

General information

1. AF8 (M22520/1-01) refers to basic tool without 
poisitioner. 
2. Wire crimp range 26 to 12 AWG.
3. The tool has a double action ratchet, and cannot be 

opened without completing the cycle.

Tool must be in open position whenever positioner is 
being installed, removed or released. Damage to turret 
head and/or crimp tool may result if this procedure is not 
followed. 

1. Tool must be in open position. 
2. Press positioner trigger latch which releases turret to 
indexing position.
3. Place positioner onto retaining ring with alignment pin 
in alignment hole. 
4. After positioner is seated against retainer ring, tighten 
socket head screw with 9/64" hex key. 
5. Refer to data plate on positioner. From colour code 
column, select the positioner colour that corresponds 
with the appropriate part number and size of contact to 
be crimped. 
6. With tool in open position, rotate until colour coded 
insert is in line with the index mark. Press turret until it 
snaps in latched position.
7. Refer to data plate. From wire size column, determine 
the selector setting that corresponds with the contact 
bring used.
8. Remove spring clip from selector knob and rotate until 
correct setting is in line with selector mark. 

Installation of positioner

1. Insert contact and prepared wire through the indenter 
opening into the positioner. 
2. Squeeze handles together until ratchet releases. 
Handle will return to open position. 

Crimping instructions

1. With tool in open position, release turret. Loosen 
screws until threads are disengaged from retainer ring 
and remove with a straight lifting motion.

Removing positioner

Caution

CONNECT