background image

Indoor 

 

12 or 24 VDC Wire Run

16 AWG - 200 Ft

18 AWG - 100 Ft

Polarity Matters!

 

Use 

Only 

Indoor 

Use 

Only 

DKGL-S6-1-064-D-3-12

Copyright 2012 DoorKing, Inc. All rights reserved.

Diode Note: Install the supplied 
diode across the positive and 
negative lines 

AFTER

 the relay to 

protect the magnetic lock from 
transient voltage spikes.

DoorKing Part Number

DKGL-S6-1

Relay

120 Glasgow Avenue 

Inglewood, California 90301 

U.S.A. 

Wire for 24 VDC or 12 VDC ONLY 

24 VDC Transformer 

(Model 1812-035) 

2

4

 VDC 

12 VDC 

12 VDC Transformer 

(Model 1812-037) 

Blue - Normally Closed 
Brown - Common 
Yellow - Normally Open 

Blue - Normally Closed 
Brown - Common 
Yellow - Normally Open 

Black 

Green 

Red Positive 

Positive 

Negative 

Negative 

Orange

LED Lock Status Sensor  

Relay Contacts 

Rated 1 amp @ 30 Volt max. 

LED Lock Status Sensor  

Relay Contacts 

Rated 1 amp @ 30 Volt max. 

Access Control Device

or Gate Operator

(Normally Closed)

Access Control Device

or Gate Operator

(Normally Closed)

Relay 

Red 

Black 

Orange 

Green 

Diode

Diode

Reviews: