Indoor
12 or 24 VDC Wire Run
16 AWG - 200 Ft
18 AWG - 100 Ft
Polarity Matters!
Use
Only
Indoor
Use
Only
DKGL-S6-1-064-D-3-12
Copyright 2012 DoorKing, Inc. All rights reserved.
Diode Note: Install the supplied
diode across the positive and
negative lines
AFTER
the relay to
protect the magnetic lock from
transient voltage spikes.
DoorKing Part Number
DKGL-S6-1
Relay
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
Wire for 24 VDC or 12 VDC ONLY
24 VDC Transformer
(Model 1812-035)
2
4
VDC
12 VDC
12 VDC Transformer
(Model 1812-037)
Blue - Normally Closed
Brown - Common
Yellow - Normally Open
Blue - Normally Closed
Brown - Common
Yellow - Normally Open
Black
Green
Red Positive
Positive
Negative
Negative
Orange
LED Lock Status Sensor
Relay Contacts
Rated 1 amp @ 30 Volt max.
LED Lock Status Sensor
Relay Contacts
Rated 1 amp @ 30 Volt max.
Access Control Device
or Gate Operator
(Normally Closed)
Access Control Device
or Gate Operator
(Normally Closed)
Relay
Red
Black
Orange
Green
Diode
Diode