background image

Installation Manual

FES20 Series ELECTRIC STRIKE

PRODUCT

FES20           Non Monitored Strike (not SCEC approved)
FES20M        Monitored Strike (SCEC approved)
FES20M-L2   Monitored Strike Lipless (SCEC approved) 
FES20M-R    Monitored Strike with additional integrated Reed Door Position Switch (DPS) (not SCEC approved)

ACCESSORIES

MORTICE LOCK FACEPLATES EQUIPPED WITH A SET OF MONITORING MAGNETS

FES20-EL 15
FES20-EL 25
FES20-EL 50
FES20-EL 75

Australian Lock Company                 FES20MR-AUS
DORMA                                             FES20MR-DOR
KABA                                                 FES20MR-KAB
Legge                                                FES20MR-LEG
Lockwood                                          FES20MR-LOC
Nova                                                  FES20MR-NOV
Other mortice lock types or cylindrical locks on request

WIRING

When installation of the strike and the mortice lock face plate is completed, connect the wiring according to list below:

Grey

Grey

Normally Open Contacts

Door Position Switch
0.5A, 30VDC

Multi Voltage 11-30VDC       12 VDC – current 220 mA   

Red  (+)                                Black  (-) 

Black  (Common) 

              Yellow  (NO-PTO); (NC-PTL)     Green  (NC- PTO); (NO-PTL)

Black  (Common) 

              Blue  (NO)                                  Orange  (NC)

Black  (Common) 

              Red  (NO)                                  White  (NC)

LSS Sensor Output 
3 A, 125 VAC;  
2 A, 30 VDC. 

DSS Sensor Output 
3 A, 125 VAC;  
2 A, 30 VDC. 

Anti-tamper Sensor Output 
5 A, 125 VAC;  
3 A, 250 VAC.

24 VDC – current 110 mA  

DPS (Door Position Status)

Power Input 

Wire output

LSS (Lock Status Sensor)

DSS(Door Status Sensor)

ATS (Anti – tamper Sensor)

Sensor Output 

122

122

122

10

5

24

26

28.5

175.6

39.5

122

26

10

28.5

3

23

5

138

122122

PRODUCT DIMENSIONS

The FES20M-R monitored Electric Strike is equipped with an integrated Reed Door Position Switch (DPS). This function requires a special 
Mortice Lock Face Plate equipped with a set of magnets to operate in combination with the FES20M-R Electric Strike. 
FSH is providing a range of face plates from 6 manufacturers (see above). Face plates from other manufacturers on request.

NOTE

FES20 Series Electric Strike factory setting is Power to Lock (PTL) .
The control circuit for the door strike is protected against reverse polarity connection. No additional diode protection required.

see new separate Manual for FES20M

Summary of Contents for FES20 Series

Page 1: ... PTO NC PTL Green NC PTO NO PTL Black Common Blue NO Orange NC Black Common Red NO White NC LSS Sensor Output 3 A 125 VAC 2 A 30 VDC DSS Sensor Output 3 A 125 VAC 2 A 30 VDC Anti tamper Sensor Output 5 A 125 VAC 3 A 250 VAC 24 VDC current 110 mA DPS Door Position Status Power Input Wire output LSS Lock Status Sensor DSS Door Status Sensor ATS Anti tamper Sensor Sensor Output 122 122 122 10 5 24 26...

Page 2: ...mm 162mm 123 1mm NOT TO SCALE 29 0 44 8 These dimensions have a tolerance of 0 8mm 0 176 0 Keeper INSTALLATION If frame is not prefabricated use the enclosed stick on template to prepare strike cut out in frame Install strike as described in diagram POSITION OF DOOR LATCH As drawn in the diagrams there should be a 1mm gap between the door latch and the front face of the strike keeper preventing th...

Page 3: ...e cover end opening hole The strike is now in the Power to Lock mode Tighten the two capstan releasing screws replace the rubber cap Replace the sticker after changing over locking function Insert the tool pin through the cover end opening hole and push down the solenoid Hold it in position and at the same time insert the tool thru the cover plate opening hole and turn the capstan wheel in the dir...

Page 4: ...er end opening hole The strike is now in the Power to Open mode Tighten the two capstan releasing screws and replace the rubber cap Replace the sticker after changing over locking function Insert the tool pin through the cover end opening hole and push down the solenoid Hold it in position and at the same time insert the tool thru the cover plate opening hole and turn the capstan wheel in the dire...