FINISH
6. Ignore Facility Code
1.
Turn the Programming Selector to
Position 6
.
2.
Press and hold Program Button until the Program LED flashes ONCE and receiver will BEEP once.
3.
Receiver LED will then give a long flash and beep.
4.
This indicates receiver will ignore the facility code before outputting the transmitter code.
Indicates receiver will ignore facility code
Release
Button
Quick Flash
and Beep
Long Flash
and Beep
2 Sec.
START
1
23
45
6
7
8
9
ABC
D
E
F
F
FINISH
8. LOW -Power Mode
1.
Turn the Programming Selector to
Position 8
.
2.
Press and hold Program Button until the Program LED flashes ONCE and receiver will BEEP once.
3.
Receiver LED will then give a long flash and beep.
4.
This indicates receiver will be put into LOW-Power mode which consumes
LESS
power than NORMAL-Power mode.
Indicates receiver is in LOW-Power mode
Release
Button
Quick Flash
and Beep
Long Flash
and Beep
2 Sec.
START
1
23
456
7
8
9
ABC
D
E
F
F
7. Learn Master Transmitters (Up to 4)
1.
Turn the Programming Selector to
Position 7
.
2.
Press and hold Program Button until the Program LED flashes ONCE and receiver will BEEP once. Receiver is now in
“Learn Mode”
and will
flash and beep every second for 10 seconds.
3.
Press the button on the master transmitter to be
“Learned”
within 10 seconds. Receiver will reset 10 second timer after each master
transmitter button has been pressed.
Master Transmitters Note:
The receiver only allows 4 master transmitters to be saved in the memory.
4.
Press other master transmitter buttons to be learned, each within a 10 second time period.
5.
After all desired master transmitters have been learned by the receiver (up to 4 total), wait for the receiver to time-out.
Timer is Reset
to 10 Sec.
After 10 Seconds
Timer Times-Out
Release
Button
One Quick Flash
and Beep
2 Sec.
1 Sec.
1 Sec.
1 Sec.
1 Sec.
Transmitter Programming Mode
Activate ONE Micro
PLUS
®
or Micro
CLIK
™ master
Transmitter
Less than 10 Seconds Idle Time
Less than 10 Seconds Idle Time
Less than 10 Seconds Idle Time
Activate another
master Transmitter
1 Sec.
1 Sec.
1 Sec.
1 Sec.
1 Sec.
Transmitter Programming Mode
FINISH
START
1
23
456
7
8
9
ABC
D
E
F
Beep
Beep
Beep
Beep
1
1
1
Beep
Beep
Beep
Beep
Beep
Activate another
master Transmitter
If you need to change the receiver from normal-power to LOW-Power
mode, follow the steps below. LOW-power mode is used in DoorKing solar
gate operator applications.
FINISH
9. NORMAL -Power Mode (Factory Set)
1.
Turn the Programming Selector to
Position 9
.
2.
Press and hold Program Button until the Program LED flashes ONCE and receiver will BEEP once.
3.
Receiver LED will then give a long flash and beep.
4.
This indicates receiver will be put into NORMAL-Power mode which consumes
MORE
power than LOW-Power mode.
Indicates receiver is in NORMAL-Power mode
Release
Button
Quick Flash
and Beep
Long Flash
and Beep
2 Sec.
START
1
23
456
7
8
9
ABC
D
E
F
F
The receiver comes from the factory already set in NORMAL-Power mode. If you need to change the receiver from LOW-Power to NORMAL-Power
mode, follow the steps below.
A. Erase ALL Memory
1.
Turn the Programming Selector to
Position A
.
2.
Press and hold Program Button until the Program LED flashes ONCE and receiver will BEEP once. Press and hold button again, LED will flash
and receiver will beep again. Press and hold button a third time, LED will flash and receiver will beep a third time.
3.
The receiver will then emit a long flash and long beep indicating ALL memory, including master transmitters have been erased from memory.
FINISH
Release
Button
Release
Button
Release
Button
2 Sec.
Press and
Hold Program
Button
Press and
Hold Program
Button
Press and
Hold Program
Button
Press and
Hold Program
Button
Press and
Hold Program
Button
Press and
Hold Program
Button
Press and
Hold Program
Button
START
1
23
456
7
8
9
A
B
C
D
E
F
Beep
2 Sec.
Beep
2 Sec.
Beep
Long
Beep
ALL Memory has