DoorKing Part Number

1815-350

#1 Green - D0 (Data 0) to #11 Aux

#2 White - D1 (Data 1) to #12 Aux

#3 Black - Ground to #13 Aux

#5 Black - Ground - “Optional Loop Detector”

#4 Red - N.O. - “Optional Loop Detector”

12VDC
Power

DoorKing 1830 Telephone Entry System Circuit Board

Red - 12VDC

Normally Open

(N.O.)

Dry Contact

Relay

Black - Ground

NC

NO

RING

HF

1816

HS

ON

SPK

VOL

FEED

BACK

RS 232

ELEVATOR

MIC

VOL

OFF

KEYPAD

3 2 1

3 2 1

3

2

1

MASTER
CODE

16AC

16AC

BAT

1NO

1NC

1C

2RY

2C

A

Z

IMC

5VDC

IMD

SPKR

COM

MIC

PSW

CGND

PHONE

1

2

3

12

34

5

6

7

8

9

10

11

12

13

14

1

2

3

4

5

6

Auxiliary
Terminal

Note:

 500 ft 

MAX

 length.

DO NOT 

use twisted wire.

Min

18 AWG

wire

100 ft 

MAX

3 Amp

12VDC

“Optional” Trigger 
Mode Wiring: 

The 

long range reader will 
ONLY operate after the 
trigger signal wires 
have been activated by 
a vehicle on the 
in-ground loop.

Approximate
Antenna
Reading
Range

SW2 DIP-Switches 2-4 Settings

SW2 DIP-Switch 1 Setting

Use the rotary switch (SW1). 
The reader will beep once 
after each change of range. It 
is also a good practice to put 
the system into “test mode” 
to benefit from the continu-
ous beeping feature while 
adjusting the range.

Set the reader to eliminate redundant readings 
of the same tag/card at certain time intervals 
by using SW2 DIP-switches 2, 3 and 4 (

Note:

 

Switches 5-8 are NOT used). 

Example:

 If the 

switches are set to: switch 2-

ON

, switch 

3-

OFF

, switch 4-

ON

) the reader will read a 

tag/card, beep and report it to the access 
controller. For the next five (5) seconds, if it 
reads the same tag/card again, it will ignore it. 
It will not beep or report it to the access 
controller.

Set for timing or trigger mode. See other side.

SW2 DIP-switches 2, 3 and 4 

MUST

 be set set to the 

ON

 position (right). This will put the 

system in 

test mode

. By choosing Timing/Trigger mode on DIP-switch 1, you can test in 

either operating mode. Test mode is used to calibrate and adjust the maximum reading 
range or maximum distance reader can read a tag/card. In timing test mode, reader sends 
out read signals at a default rate of 10Hz. After each successful tag/card read, you will hear 
a beep. As long as a tag/card is within range and in sight of the antenna, you will hear ten 
beeps per second. This feature helps when adjusting the reader’s reading range, using the 
rotary switch SW1. In “trigger” test mode, the same is achieved in the presence of a valid 
trigger signal (car on loop).

Long Range Reader Control Board

Time Interval

Switch 4

Switch 3

Switch 2

ON
OFF
ON
OFF
ON
OFF
ON
OFF

ON
ON
OFF
OFF
ON
ON
OFF
OFF

ON
ON
ON
ON
OFF
OFF
OFF
OFF

0 sec (Test Mode)
1 sec
5 sec
10 sec
15 sec
20 sec
25 sec
30 sec

Switch 1 OFF -  Timing Mode
Switch 1 ON  -  Trigger Mode

Test Mode

Switches 5-8
NOT used:
set to OFF
Position

120 S. Glasgow Avenue

Inglewood, California 90301 

U.S.A.

SW1

0
1
2
3
4
5
6
7
8
9

8 ft

9.5 ft

11 ft
12 ft
13 ft
14 ft
17 ft
19 ft
21 ft
25 ft

#1 Red

#9 - Blue - Trigger Mode - for In-Ground Loop

#10 - Black - Trigger Mode - for In-Ground Loop

Orange

Brown

Not Used

#2 Black

#2 Black - Ground

#3 Yellow - D0 (Data 0)

#4 Gray - D1 (Data 1)

#5 Purple - TXD (Transmit Data)

#6 White - RXD (Receive Data)

Note:

 Cable should be in

conduit for vandal protection. 

Note:

 The Blue and 

Black wires are 

ONLY 

necessary if a in-ground 
loop will be used 
(Trigger Mode).

2-Conductor

Power Cable

9 ft
Antenna
Cable

Long Range

RFID Antenna

PW

R

DE

T

FA

IL

HIG

H

F
R
E
Q

LOW

RESE

T

FREQ

Vehicle

Lo

op

Detector

In-Ground

Loop