1812-065-V-12-14
16
MASTER
CODE
ON
MASTER
CODE
ON
EARTH
GND
1
CENTRAL
OFFICE
PHONE
IN
PHONE
OUT
HOME
2
3
4
5
6
7
8
SW1
ENTRY
BY-PASS
1875-010
1
CENTRAL
OFFICE
EARTH
GND
PHONE
IN
PHONE
OUT
HOME
2
3
4
5
6
7
8
SW1
ENTRY
BY-PASS
1875-010
Be sure to properly ground
ALL
1812s.
See page 13 for
acceptable grounding sources.
Relay 2 to Access Control Device
To 24 VAC Supplied Transformer
Relay 1 to Access Control Device
Relay 2 to Access Control Device
To 24 VAC Supplied Transformer
Relay 1 to Access Control Device
1.8 Wire Multiple 1812s: Telco/Internet - Telephone Mode
Cat5e
Cat5e
Cat5e
By-Pass Board
The By-Pass board is
NOT
optional and must be
installed as part of multiple 1812s “Telephone Mode”
system.
See page 11 for complete information.
Multiple 1812s:
PHONE IN #3 connects to 1st 1812 Main Term #1.
PHONE IN #4 connects to 1st 1812 Main Term #2.
PHONE OUT #5 connects to Last 1812 Main Term #5.
PHONE OUT #6 connects to Last 1812 Main Term #4.
16.5
VAC
See previous
2 pages for
wiring and
information.
See previous
2 pages for
wiring and
information.
See previous 2
pages for more
information
about Telco
OR
Internet wiring.
Use the previous 2 page’s wiring diagrams and
information to wire multiple 1812s
except
for
the By-Pass board’s “PHONE IN” and “PHONE
OUT” terminal connections.
Up to five (5) 1812s
may be wired in series
to the By-Pass board
using the method shown on this page: 1st
1812’s PHONE OUT to 2nd 1812’s PHONE IN;
2nd 1812’s PHONE OUT to 3rd 1812’s PHONE
IN, etc. Connect the last 1812’s PHONE OUT
back to By-Pass board’s PHONE OUT.
Note:
Each
1812 must be
programmed for MULTIPLE
SYSTEMS, have a unique
ATTENTION NUMBER (See
2.3.2 and 2.3.3) and have a
unique MASTER CODE (See
2.2).
Note: The 1812 that is
connected directly to the
homeowner’s phones (1st
1812)
must
have its
“Number of Rings”
programming set for 1 less
than the other 1812s wired
in series (See 2.3.9).
Check Polarity of Telephone Line
See previous 2 pages for information.
Be sure to properly ground
ALL
1812s.
See page 13 for
acceptable grounding sources.
Ground 12 AWG Min.
Phone Out
Phone Out
Phone In
Phone Out
Phone In
Phone Out
Phone In
Phone Out
Phone In
Phone In
Phone In
Phone Out
Ground 12 AWG Min.
1st 1812
Phone Mode
(E.g.: 5 Rings)
2nd 1812
Phone Mode
(E.g.: 6 Rings)
3rd 1812
Phone Mode
(E.g.: 6 Rings)
4th 1812
Phone Mode
(E.g.: 6 Rings)
5th 1812
Phone Mode
(E.g.: 6 Rings)
Phone
Company
Internet
Homeowner’s Phones
(LAN/Cordless)
Maximum 1812 Wiring Configuration
Ground
12 AWG Min.
TIP
TIP
TIP
RING
RING
RING
TIP
RING
OR
Fiber / V
olP
Device
Phone
Jack
Phone
Jack
Homeowner’s
LAN/Cordless Phones
TIP
Older Lines
Green Wire (+)
Older Lines
Red Wire (-)
RING
77
88
99
44
55
66
00
Push Button
Push Button
To Call
To Call
77
88
99
44
55
66
00
Push Button
Push Button
To Call
To Call
77
88
99
44
55
66
00
Push Button
Push Button
To Call
To Call
77
88
99
44
55
66
00
Push Button
Push Button
To Call
To Call
77
88
99
44
55
66
00
Push Button
Push Button
To Call
To Call
Main
Terminal
1871-010
Phone In
(1-2)
Phone Out
(4-5)
18
17
16
Com
15
N.C.
14
N.O.
13
Com
12
N.C.
11
N.O.
10
9
8
7
6
5
RING
4
TIP
3
GND
2
TIP
1
RING
24
VAC
MAST
MAST
COD
Relay 1
Relay 2
Power
16.5
VAC
Main
Terminal
1871-010
Phone In
(1-2)
Phone Out
(4-5)
MAST
MAST
COD
Relay 1
Relay 2
Power
18
17
16
Com
15
N.C.
14
N.O.
13
Com
12
N.C.
11
N.O.
10
9
8
7
6
5
RING
4
TIP
3
GND
2
TIP
1
RING
24
VAC
Last 1812
1st 1812
Summary of Contents for 1812 Classic
Page 2: ......