background image

OFF

Opening

Direction of

SECONDARY

Operator

2

3

Terminal #4 is output from plug-in exit loop detector installed in EXIT loop port.

Same opening directions as illustrated above for the primary operator type. 

• Switch 2 will be the OPPOSITE setting as switch 1.

Note: SW1, switch 7 MUST also be ON when using a secondary operator.

Exit Loop Port

Output

Open Input

ON (normal) Terminal #4 is normal open command.

OFF (normal)

ON

OFF

ON

Reverse

Not Used

Overlapping

Gates

5

6

Terminal #8 is a standard Reverse input.
On setting is NOT used.
Both operators start at the same time. 
Secondary operator opens 1-2 seconds before primary operator. Vice-versa when closing.

OFF

ON

Single

Dual

Switch must be OFF for single operator. 
Switch must be ON when (dual) operators are used.

Input Power

Switch MUST be in the OFF position.

OFF

8

7

OFF

ON

Auto-Close

Timer

4

Auto-close timer is OFF. Manual input required to close gate.
Auto-close timer is ON. Adjustable from 1-23 seconds.

Switch Function

Setting

Description

1

Opening Direction of PRIMARY Operator

SW 1

SW 2

1

ON

2

3

4

5

6

7

8

1

ON

2

3

4

SW 1 DIP-Switches

SW 2 DIP-Switches

Note: After a DIP-switch 

setting is changed, press the 

reset button for new settings 

to take effect.

Switch

Function

Setting

Description

1-OFF
1-OFF

1-ON
1-ON

2-OFF

2-ON

2-OFF

2-ON

Relay activates when gate is fully open. 
Relay activates when gate is not closed.
Relay activates when gate is opening and open. Shadow loop setting if used. 
Relay activates when gate is opening and closing.

Spare

Leave in the OFF position.

OFF

Relay

Operation

1 and 2

3
4

1 second delay to disengage maglock. 
Leave in the OFF position if a maglock is NOT used.

ON

OFF

Maglock Used

No Maglock

Power safety and opening devices 

that require 115 VAC power.

Three 115 VAC Convenience Outlets

Deluxe

115 VAC

Control

Box

Key Switch

(Dry contact)

Keypad

(Dry contact)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Switch 3 ON

Controls must be far 

enough from the gate so 

that the user is prevented 

from coming in contact 

with the gate while 

operating the controls.

Do not power any control 

devices from the circuit 

board other than low 

voltage devices.

Com

Com

Com

N.O.

N.O.

N.O.

N.O.

Com

Com

N.C.

Power Com

Relay Com

Relay

Power

Rela

y

Co

m

Powe

r

Magnetic Lock

4-Wire

RF Receiver

Safety Opening Device

(Dry contact)

Switch 3 

MUST be 

ON.

Telephone Entry

Note: Must use a 

separate power source. 

Note: Circuit board provides 

24 VDC to power maglock. 

Contact rating is 1 amp 

maximum at 24 Volts.

 

SW 1

1

ON

2

3

4

5

6

7

8

SW 2

1

ON

2

3

4

Connect optional control devices to 

the main terminal. Use 18 AWG wire 

for all low voltage wiring, maximum 

distance 3000 feet. Use a low voltage 

surge suppressor, (DoorKing P/N 

1878-010) if low voltage wire runs 

exceed 1000 feet. All control device 

inputs to the terminal must be 

NORMALLY OPEN.

Low V

oltage Common

Low V

oltage Common

Low V

oltage Common

Low V

oltage Common

Dr

y Relay Contact

Alarm Reset

Dr

y Relay Contact

24 VDC - 250 ma max.

Full Open

Full Open

Full Open

Standard Reverse

Not Used

Not Used

DC Lock Power Common

24 VDC Maglock Power

12 V
olt Batter

y Input

Low V

oltage Common

24 V
AC Input

24 V
AC Input

Main Terminal

3-Wire

RF Receiver

Reversing input on 

Terminal #8 

functions ONLY 

while the gate is at 

the FULL OPEN 

position or during the CLOSING cycle. It 

MUST NOT be used as an input for a 

secondary entrapment protection device 

during the OPENING gate cycle. Refer to 

Secondary Entrapment Protection Wiring 

in the Wiring/Owner’s manual.

OFF setting.

Opens clockwise.

ON setting.

Opens counter-clockwise.

ON setting.

Opens counter-clockwise.

OFF setting.

Opens clockwise.

Left-Side

Right-Side

QUICKSTART “BASIC” GUIDELINES FOR MODEL 115 VAC 6004 - DIP-SWITCH AND WIRING REFERENCE

120 Glasgow Avenue

Inglewood, California 90301

U.S.A.

Model 115 VAC 6004 is intended for installation only on swing gates used for vehicles.

Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the 

6004 Actuator Arm and Control Box Mounting manual and the 115 VAC Control Box Wiring/Owner’s manual.