background image

 

 

 

 

 

From 

Inverter

115 VAC 

Input

115 VAC Output

To Gate Operator 

System 1

To
Inverter

To
Inverter

Hot

Neutral

Ground

Hot

Neutral

Ground

2

1

4

3

6

5

8

7

10

9

Gate Operator

Open Terminals

INPUT
AC
POWER

OUTPUT
AC
POWER

Insure that both AC Power Input and AC Power Output switches are in the OFF (down) position before connecting any wires.

2

1000 Watt inverters (1000-080) can use one (1) or two (2) batteries; 1500 Watt inverters (1000-081) use two (2) batteries.

1

1

2

J8

J6

J1

3

4

Insure that J1 

IS NOT

 plugged into the circuit board.  This plug is inserted only after the batteries are connected.

3

Insure J6 and J8 ARE inserted into the circuit board before connecting batteries.

4

4

1

1

2

2

Connect 115V Output to gate operator AC input terminals.  Connect relay 1 (Term 7 & 8) to 
gate operator 1 open terminals; relay 2 (Term 9 & 10) to gate operator 2 open terminals.

Connect 115 VAC source voltage to AC input 
terminals.

Connect RED wire from J1 to POSITIVE terminal on battery.  Connect BLACK wire from J1 to 
NEGATIVE terminal on battery.  

Be sure that J1 IS NOT plugged into the board at this time !

3

4

4

If using two batteries, connect batteries in PARALLEL: Positive to Positive; Negative to 
Negative.  

DO NOT CONNECT BATTERY TO INVERTER AT THIS TIME.

5

5

Connect battery to inverter terminals: Positive to RED terminal; Negative to 
BLACK terminal.  

Insure that J1 IS NOT plugged into the circuit board .

6

6

Insure all wiring is connected to the circuit board and inverter, and that 
the battery is connected to the inverter.  Plug J1 into the circuit board.

DOORKING, INC.,  INGLEWOOD, CA  90301

Date:

Dwg. No.

Rev.

Title:

4/09

A

M1000-Wire

1000 Inverter
Wire Connections

J3

J2

J4

115 VAC Output

To Gate Operator 

System 2

Gate Operator

Open Terminals

3

1

1000-065-B-7-09  

Page 

11 

Summary of Contents for 1000-080

Page 1: ...wer Backup Systems Owner s Manual DoorKing Inc 120 Glasgow Avenue Inglewood California 90301 U S A Phone 310 645 0023 Fax 310 641 1586 www doorking com P N 1000 065 REV B 7 09 Copyright 2001 DoorKing...

Page 2: ...Page 2 1000 065 B 7 09...

Page 3: ...manual without notice and without obligation of DoorKing Inc to notify any persons of any such revisions or changes Additionally DoorKing Inc makes no representations or warranties with respect to th...

Page 4: ...Page 4 1000 065 B 7 09...

Page 5: ...Specifications 8 4 Mounting 9 5 Read Before Wiring 10 6 Wiring Instructions 10 7 LED Status Indicators 12 8 Battery Test and Reset Push Buttons 12 9 Switch Settings Terminal Description 14 10 Status r...

Page 6: ...gy Hazard 12 V 35 Ampere hour battery Dangerous voltages are present even when the AC is off Remove personal metal items such as rings bracelets necklaces and watches when working with electrical circ...

Page 7: ...e parts inside this unit are energized from the battery supply even when AC power is disconnected CAUTION Risk of electrical shock AC Input and AC Output terminals can be energized even with AC INPUT...

Page 8: ...tput Wave Form Modified Sine Wave DC Input Voltage 10 15 VDC Low Battery Alarm 10 5 VDC 5 V 1000 080 9 5 VDC 5 V 1000 081 Low Battery Shutdown 9 5 VDC 5 V Frequency 60 Hz Efficiency 90 No Load Current...

Page 9: ...alled The system operates best when it can be installed as physically close as possible to the equipment that it is intended to operate during power outages This reduces line loss The effective capaci...

Page 10: ...Y A SNAP THIS IS NORMAL DON T LET IT SCARE YOU WARNING Never disconnect the batteries while the system is delivering power or the battery charger is operating Always turn the system OFF first 6 Wiring...

Page 11: ...perator 1 open terminals relay 2 Term 9 10 to gate operator 2 open terminals Connect 115 VAC source voltage to AC input terminals Connect RED wire from J1 to POSITIVE terminal on battery Connect BLACK...

Page 12: ...ng a trickle charge to it to maintain the full charge TEMP RED LED indicates that the battery is not being charged because the temperature is outside the battery safe operating range 23 F 4 C to 126 F...

Page 13: ...RESET BATT TEST INPUT AC POWER OUTPUT AC POWER HRT BEAT DIAGNOSTIC UTIL OPER INV ON B BAD B OK BULK TRICK TEMP SHDN 110V ON 1000 065 B 7 09 Page 13...

Page 14: ...er a shut down condition When primary AC Utility power is lost the system will provide AC power to the gate operator s until the battery is too weak to continue operation At this time the system will...

Page 15: ...1000 065 B 7 09 Page 15 1 2 3 4 5 6 7 8 9 10 RESET J2 J3 J6 J4 J8 J1 BATT TEST INPUT AC POWER OUTPUT AC POWER HRT BEAT DIAGNOSTIC UTIL OPER INV ON B BAD B OK BULK TRICK TEMP SHDN 110V ON...

Page 16: ...l change see status report table below Status Report Table ASCII Character Hex Value Description 0 30 AC failure detected 1 31 AC present detected 2 32 System switched to battery operation 3 33 System...

Page 17: ...2 Volt 35 AH Battery and Cable Assembly Order this to add a second battery to the 1000 Watt inverter system 1801 005 12 Volt 35 AH replacement battery 1000 044 Battery Cables 2355 010 Circuit Board 05...

Reviews: