Boiler temperature controller EKOSter 420
12
Blow.Type : 01
14.3 Work Parameters - Modulation of blower operation
Blower
Modulation : yes
14.2 Work Parameters - Blower type
The parameter for setting of one of two
characteristics of adjustable blower
power, depending on the type mounted
on the boiler.
This parameter causes the modulation
of the blower motor operation to go on or
off. When modulation is enabled ("yes"
symbol), the fan will reduce its speed
when the boiler is about to reach the set
temperature and will increase its speed
when the temperature of the boiler
drops, disabled modulation is indicated
by the "no" symbol.
Note:
Modulation of the blower is performed only in the
hysteresis range i.e. in a temperature range between the boiler
setting and that resulting from the hysteresis parameter - below
the hysteresis, the blower operates at maximum power.
14.4 Work Parameters - Adjusting the maximum power of the blower
This parameter allows you to set the
maximum operating power of the blower
Blower
Max.Power: 100%
Note:
Blower type 1 - applies to RV05, RV14.
Blower type 2 - applies to RV12 and others with power of 80
W, based on EBM/EMC If the type of installed blower is not
known, it is recommended to choose setting 1.
!
!
Change range: 01 / 02
Factory setting: 1
Change range: yes/no
Factory setting: no
Change range: 30%
÷
100%
Factory setting: 100%