DJPOWER

 

7

 

4.

4

 

Mounting 

Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes. 

4.

4

.1

Orientation 

For safety reasons, we do not recommend mounting the product in any capacity. Operate the product 
while it is on the ground only, and make sure there is adequate room for ventilation, configuration, and 
maintenance. 

4.

4

.2

Rigging 

DJPOWER recommends using the following general guidelines when mounting this product. 

Before deciding on a location for the product, make sure there is easy access to the product for
maintenance and programming purposes.

Make sure that the structure or surface onto which you are mounting the product can support the
produ

ct’s weight (see the Technical Specifications).

When mounting the product on the floor, make sure that the product and cables are away from
people and vehicles.

5

 

OPERATION 

5.1

 

Preparing for Operation 

After checking that all the parts are intact and complete, position the machine on flat.

Fill the consumable into feed port when power off.

Always connect the product to a grounded circuit. Before power on, make sure it is connected with
the rated voltage.

Turn on the machine, it will immediately start heating up.

5.2

 

On-device Control Panel 

To access the control panel functions, use the four buttons located underneath the LCD display. 

Button 

Function 

<MENU> 

Switch menu pages to select a function 

Summary of Contents for V-3

Page 1: ......

Page 2: ...2 AC PLUG 6 4 4 DMX LINKING 7 4 4 MOUNTING 7 4 4 1 Orientation 7 4 4 2 Rigging 7 5 OPERATION 7 5 1 PREPARING FOR OPERATION 7 5 2 ON DEVICE CONTROL PANEL 7 5 3 ON DEVICE CONTROL MODE OPERATION 8 5 3 1 Programming 8 5 3 2 Menu Map 8 5 5 DMX MODE OPERATION 10 5 5 1 Starting Address 10 5 5 2 DMX Mode Menu Map 11 5 5 3 DMX Channel Assignments and Values 11 5 4 CORRESPONDENCE OF SPARK HEIGHT SPARK DENSI...

Page 3: ... 2 PRECAUTION FOR USE 13 7 TECHNICAL INFORMATION 14 7 1 MAINTENANCE 14 7 2 STORAGE 14 7 2 1 Machine Storage 14 7 2 2 Spark Seed Storage Recycling 15 7 3 GENERAL TROUBLESHOOTING 15 7 3 1 Device Error Description 15 7 3 2 Device Error Menu Map 15 ...

Page 4: ...addition keep the box and contents for inspection 1 3 Symbols Symbol Meaning Caution Critical installation configuration or operation information Not following these instructions may make the product not work cause damage to the product or cause harm to the operator Important Important installation or configuration information Failure to comply with this information may keep the product from worki...

Page 5: ...ccess to the machine The operation noise is lower than 80 dB without harm to ear No need to wear ear protection when close to the working machine Eye protection is always required when operate the machine closely 1 5 2 Mounting and Rigging For safety reasons we do not recommend mounting the product in any capacity Operate the product while it is on the ground only The product is for indoor use To ...

Page 6: ...eable parts Any reference to servicing in this User Manual will only apply to properly trained certified technicians Do not open the housing or attempt any repairs which can lead to damage or malfunction In the event of a serious operating problem stop using the product immediately Use only DJPOWER Spark Seed PRO K Keep this User Manual for future use If you sell the product be sure that the purch...

Page 7: ...DJPOWER 4 Compact size with belt drive less noise Higher and denser spark quicker eruption speed amazing effect 2 3 Product Overview 2 4 Product Dimensions 205 mm 200 mm 255 mm ...

Page 8: ... min Maximum Continuous Duration 100 Output 30s Continuous Output Consumable Type for Standard Output Test PRO K Accessory Power Cord Wireless Controller Controller Model Wired Controller Controller Model Placement Mounting Horizontal Inclined Vertical Hang Upside Down Rigging Trussing Rotating Nozzle Deflector Features Operation Noise 1 m 80 dB Control On device Manual Control LCD control board W...

Page 9: ...ct the product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch 4 2 AC Plug The Spark Machine V 3 comes with a power input cord terminated with a Seetronic Powerkon connector on one end and an EU plug on the other end EU China market If the power input cord that came with your product has no plug or if you need the change the...

Page 10: ...Make sure that the structure or surface onto which you are mounting the product can support the product s weight see the Technical Specifications When mounting the product on the floor make sure that the product and cables are away from people and vehicles 5 OPERATION 5 1 Preparing for Operation After checking that all the parts are intact and complete position the machine on flat Fill the consuma...

Page 11: ... that first option or you will see the selected value Press MENU repeatedly to switch menu pages Press ENTER to switch between current menu page and Standby Page at any time 5 3 2 Menu Map Display Description Parameter Range Preparing Page The machine is heating up The machine could only start working when reach the pre set target temperature 530 600 Standby Page Finished heating up ready to work ...

Page 12: ...um 1 10 DMX Configuration Page Press and to set the DMX starting address 1 512 5 4 Wireless Remote Control Mode Operation This mode will allow you to control the Spark Machine V 3 using the wireless controller W 2 This consists of the transmitter and the receiver Any one or more W 2 transmitter can work with any one or more W 2 receiver no paring procedure needed You may control up to 4 independen...

Page 13: ...onds The screen display as below Release the button Spark stops The screen display as below Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket on the product 5 5 1 Starting Address When selecting a starting DMX address always consider the number of DMX channels If you choose a starting address that is too high you could restrict the access to some of the product ...

Page 14: ...tinuous output with LCD showing Spark OFF For longer output just turn on spark again via DMX controller Status Pages The selected DMX starting address is 1 The machine is having error Error code is E0 1 512 Refer to General Troubleshooting chapter to for a brief description of each error code 5 5 3 DMX Channel Assignments and Values Channel Function Value Description 1 Spark Height 000 009 Spark O...

Page 15: ...evel 3 Density level 4 Height level 5 Height level 6 Height level 7 Height level 8 Height level 9 Density level 5 Density level 6 Density level 7 Density level 8 Density level 9 Height level 10 Maximum Density level 10 Maximum The internal temperature increases dramatically after continuous high level output which might cause clogging and failure 5 5 Advanced Settings Interface 5 5 1 Enter And Exi...

Page 16: ...d in and used for the DJPOWER Spark Machine after successfully identified by swiping Consumable ID card 6 SPARK SEED Spark Seed is the consumable specially designed for DJPOWER Spark Machine to create light golden color cold firework for stage effect Make sure to fill the Spark Seed through the feed port on the top of the fixture and when power supply is off Use Dry Chemical Extinguishers once lig...

Page 17: ...run your DJPOWER V 3 on a monthly basis to achieve the best performance 7 2 Storage 7 2 1 Machine Storage Before storing the machine empty the storage bin clean it as described in the Maintenance section And keep the machine in dry cool place Empty the storage bin Remove the power cord from mains power and allow unit to cool down Empty the storage bin through feed port by inverting the machine Run...

Page 18: ...k Seed Recycling Store the unfinished Spark Seed in the Recycling Tube with the Funnel Keep it sealed and away from moisture 7 3 General Troubleshooting 7 3 1 Device Error Description When error happens device will stop working and heating system shuts off automatically LCD shows corresponding error code 7 3 2 Device Error Menu Map Errors Display Possible Cause Over heat shutdown The heating syste...

Page 19: ...rmocouple tripped off Open circuit or no connection of thermocouple Internal temperature too high The internal temperature is higher than 60 Motor error Stepper motor cannot be reset Power line frequency abnormal Power input frequency is abnormal ...

Page 20: ......