background image

Remove the protective film on the shell. 

Remove the attachment and check the 

type and quantity

5

1.5Unpacking

Before unpacking, check whether the outer packing

machine is well and the machine model is consistent 
with you purchased.

Remove the shipping tape on the door and evaporator 

(ice tray) 

Plastic adjustment foot 4  pieces

DB75A/W, DB95A/W,

DB125A/W 

plus 4 counter installation foot

Plastic ice scraper
Inlet pipe           
Drain  pipe                                    
Drain pipe clamp         
Specification               
Warranty card                   1             

1
1
1
1
1

The ice maker is not suitable for outdoor use  , don't 
get close to the location of the source of heat or direct 
sunlight.

Working environment temperature should be5 

  ~ 38

,the normal work of the water temperature should be 

 ~ 35 

  . If the ice machine long time work beyond

the normal working temperature range , may affect ice
-making capacity.

Ice machine should be installed in a solid, flat ground.

Don't put any items in front of the ice machine ventilation
window.

Ice machine can not work in sub-zero temperatures. To 
prevent  water supply line fault  , when air temperature
is  below  freezing   ,   please drain the water in the ice 
machine    (see  "preparations  for  long-term  storage  of
ice machine").

1.7The ice maker level adjustment

Adjust  the  four  foot  adjustable  part  twist  in  the  end, 
andthen adjust the foot twist into ice machine bottom
corresponding installation hole.

Move the ice machine to install location.
Use spirit level to maker ice machine keep horizontality.

Notice

Using counter board foot, ice machine level adjustment
do not use the method of adjustment level in the bottom
of  foot  pad  hard  objects.  To  ensure  the  four  foot  of  ice 
machine touches the ground steady, to prevent vibration
when machine is running.

1.8 Power supply

warning

Wiring used in power supply must be reliable grounding, The
wiring use must accord with the local countries and regions 
laws and regulations.

Ice machine starting, allows the voltage fluctuation
range is + / - 10% of rated voltage.
The ice maker must have a separate fuse/circuit 
breakers.
The maximum capacity of this series machine we
recommended fuse is 15 A.

1.9Water supply/drainage

The water supply

According  to  the  local  water  supply  condition,  to 
determinewhether to need to install the watertreatment
system, used to prevent formation sediment, and filter
out the impurities, removethe smell of bleach.

warning

Ice machine must be connected to a drinkable water.

Please follow the following guide to install water supply
pipe:

Don't put ice machine connected with hot water .

If the water pressure over the allowed maximum 
feed  waterpressure  of  (5  bar),  pls  buy  a  water 
pressure regulator.
Ice machine must be installed  water valve in front 
of all theinlet pipe.

Drainage

When installing a drain, should prevent water poured into 
the ice machine or the ice storage bin , please observe the
following guidelines:

Main drain should be thick enough, to be able to 
dischargeall the water in the drain pipe.

Ice storage bin and water-cooling condenser pipes  
should be separated, and coated heat preservation 
material, in order to prevent condensation.
Every one metre long drainage pipe must have a drop 
of 2.5 cm. And there can not be bended.

Good

Downward sloping

Effect is bad

Effect is bad

Upward sloping

DB Series  Internet Of Things ice Machine

1.6 Choose installation location

Summary of Contents for DB Series

Page 1: ... contaienricemachineinstallationmaintenancemanual This manual contains the following ice machine DB75A W DB95A W DB125A W DB175A W DB215A W DB320A W DB430A W DB510A W DB710A W DB1050A W DB1500A W DB1950A W DB2200A W ...

Page 2: ...failure rate Please read and understand this manual it contains valuable information about installation use and maintenance If you encounter issues not covered in this manual please contact our company or the company maintenance agent at any time The content involved in this manual of adjustment maintenance and cleaning does not belong to the warranty scope Note Please Keep This Manual properly Th...

Page 3: ...aker Level Adjustment Power Supply Water Supply Drainage Check after Installation Ice Machine Running Main screen Main Menu and Sub menu WIFI Ice Machine Running Processes Instructions Maintenance Cleanning Condenser Cleaning The machine stop winterizing WIFI Cloud Service Ice Machine Touch Screen Operation Instructions 3 2 3 3 Servicing Servicing 1 2 1 1 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 Choose in...

Page 4: ...ient temperature making ice with high efficiency stable and reliable work Removable water tank design make cleaning and maintenance easier Plastice door Air inlet Adjustable foot Service label Touch screen Auxiliary Air outlet Air outlet Water output Water input Power line Ice machine can connecr to internet through WI FI customer can check and control icemachine with iphone The ice machine work d...

Page 5: ...e of split ice machine shape Touch screen Touch screen Plastice door Plastice door Air outlet Auxiliary Air outlet Adjustable foot Power line Water input Water output 2 DB Series Internet Of Things ice Machine ...

Page 6: ...6 76 Power Supply Model Power W Current A Refrigerator Liquid amount g Ice Output kg Ice Storage kg Unit kg 24h Text Environment Ambient temperature 21 water temperature 10 Unit kwh 100P 45kg Unit L 100P 45kg Unit Centimeter bar bar 3 DB Series Internet Of Things ice Machine R404a R404a R404a R404a R404a R404a 38 45 40 40 40 60 80 100 115 DB75A DB95A DB125A DB175A DB215A DB255A 220VAC 50Hz 1ph 291...

Page 7: ... 5 74 5 74 5 56 7 76 7 76 7 76 7 92 2 62 0 62 0 59 5 68 5 79 5 77 5 84 5 84 5 154 2 154 2 165 0 174 0 185 0 187 5 194 5 194 5 164 7 Unit kg 24h Text Environment Ambient temperature 21 water temperature 12 Unit kwh 100p 45kg Unit L 100P 45kg Unit Centimeter 4 DB Series Internet Of Things ice Machine Power Supply Model Power W Current A Refrigerator Refrigerating Capacity g Ice Output kg Ice Storage...

Page 8: ...vel in the bottom of foot pad hard objects To ensure the four foot of ice machine touches the ground steady to prevent vibration when machine is running 1 8 Power supply warning Wiring used in power supply must be reliable grounding The wiring use must accord with the local countries and regions laws and regulations Ice machine starting allows the voltage fluctuation range is 10 of rated voltage T...

Page 9: ...grounding right Ahead of ice maker have adequate space to makethe air flow Ice making machine in the ambient temperature between 5 38 C Ice machine inlet water temperature of the installationpoints remain between 5 32 C Ice machine and ice storage bin already clean Ice machine running 2 1WIFI cloud service ice machine touch screen operation instructions 2 1 1 Main screen Ice making button press ic...

Page 10: ... s or the water full then the water inlet valve will close Pump starting after 30 s then after 20 s drain valve open After 20 s hot air valve water pump and drain valve closed Precooling water inlet valve compressor cooling fan Precooling time 40 s Cooling fan starting water inlet valve is opened water level detection probe detect the water full then the water inlet valve closed If 40s finish into...

Page 11: ...degrees downtime drainage after 30s ice receiving drainage time 0 30 s adjustable end of the ice receiving drainage time is over even if there still have drainage time Before shipment ice machine has been running and debugging in factory In general the new machine without any debugging In order to en sure the ice machine normal operation in the following cases need to be run to check First start R...

Page 12: ...y inside the machine may cause severe damage to machine parts The causes of failure is beyond the scope of the warranty For air cooled ice machine please follow these steps 9 3 1Cleanning It is forbidden to use water jet flushing the ice machine Shall not use any alcoholic liquids to clean or disinfect ice machine otherwise may cause crack of plastic parts Please do not remove the roof and ventila...

Page 13: ...5 38 degrees whether the water temperature is too high or too low water temperature range 5 32 degrees 2 Write down the serial number of the machine and computer board andcall free telephone on the service label 3 The circuit diagram d Is the refrigerator storage is full can clean up after work D Is the refrigerator storage is full can clean up after work Power Section Microprocessor part WIFI par...

Page 14: ...alve Hot Air Valve Ice Receiving Probe Water Level Probe WIFI part WIFI Antennas Water baffle plate switch High Pressure Evaporation Temperature Condensation Temperature Cleaning Operation Microprocessor part Connect the Dispaly Screens Ground Connection Display Screens Power Section Wiring diagram of DB series split nachine ...

Page 15: ......