Freezing - compressor, cooling fan,
water pump, the water inlet valve
。
Running check
Notice
Confirm the water faucet open, ice machine has been
switched on.
The pipe inspection. Check all the pipes and pipe joint
, and to ensure no leakage.
The thickness of the ice bridge inspection. The thickness
of the ice bridge set up in 3 mm from factory, if you need
to adjust, pls click touch screenSettings button then it will
have user Settings menu.
8
Energy storage---compressor, water pump.
Closed cooling fans ahead of time, accelerate the
speed of ice receiving, improve the efficiency of the
ice maker.Condenser temperature probe by detecting
condensation temperature, determine the length of
the storage time, storage time means fan shut early
time is 0-60 s.
Ice receiving --- compressor, hot air valve,
drain valve, water pump, water inlet valve.
Hot air valve is opened, the ice dish began to let the bottom
of the ice to melt, on the effect of gravity then loss. Inspect
the condition of the magnetic switch when ice receiving,
magnetic switch is closed----to disconnect, ice receiving
finish, closed once agian within 30 s , return to the precooling
stage , ice making again ;After 30 s closed magnetic switch is
not closed, downtime, screen shows filled with ice. If the
magnetic switch is open, the ice magnetic switch is closed
whithin 4 minutes after ice receiving, then return to the
precooling stage, ice making again, magnetic switch is still
open after 4 minutes then machine will be stop , the screen
shows magnetic switch failure. When ice machine into the
ice receiving process 2 minutes, the evaporator temperature
below zero degrees , downtime . drainage after 30s ice
receiving , drainage time 0---30 s adjustable,end of the ice
receiving, drainage time is over, even if there still have
drainage time.
Before shipment ice machine has been running
and debugging in factory. In general, the new
machine without any debugging. In order to en
sure the ice machine normal operation, in the
following cases, need to be run to check:
•
First start,
•Restart after long downtime
•After cleaning and disinfection
The thickness of the ice bridge inspection. The thickness
of the ice bridge set up in 3 mm from factory , if you need
to adjust, pls click touch screen Settingsbutton then it will
have user Settings menu.
Water pump start, ice machine starting into freezing cycle. In the
freezing process, if ice receiving detection probe can not detect
water, screen display ice receiving detection probe failure and
machine stop. Water levels fall in the process of ice making, when
the water level probe detect the water was fullthen the water valve
opens, the second filling water, water level detection probe after
the expiration of the water inlet valve closing (similarly can set
multiple moisturizing). In the freezing period of 6 minutes, testing t
he temperature of the evaporator and condenser probe, if evaporator
temperature higher than0
℃
, report downtime, screen displayed
refrigeration system failure; If the temperature of the condenser is
higher than 55
℃
, alarm warining, screen displayed radiator is dirty
, if higher than 65
℃
, report downtime, screen displayed high
temperature protection. Condenser temperature probr by detecting
condensation temperature,then determine the length of the storage
time; When ice probe does not come into contact with water, delay
set time, into the process of energy storage.
DB Series Internet Of Things ice Machine
Ice bridge thickness: 3mm