background image

 VR4040CS-AL Vapor Hose Coupler 

 

VR4040CS-AL 

              090121 REV 0                                                   3 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

These instructions and recommendations are provided to ensure proper 
operation and long service life of Dixon Bayco VR4040CS-AL. Parts are 
identified by the item number on the assembly drawing and parts list. 

SEAL REPLACEMENT FOR DIXON BAYCO VR4040CS-AL VAPOR 
HOSE COUPLER 

1. Hold the cage (2) and undo the machine screws (6) using a 
screwdriver. 

2. Remove the cage (2) and visually inspect the cage (2) and the 
button (11). If the cage (2) and the button (2) are worn or damaged, 
replace with new ones. 

**The button (11) is tightened onto the probe of the cage 
(2) permanently in the factory. Please order the cage (2) 
with the button (11) for replacement.** 

3. Push the poppet (3) into the coupler and hold. Remove the O-Ring 
(8) from the poppet (3). Remove the poppet (3) and the spring (5). 