11
dixonvalve.com • 800.789.
1718
Dixon B
5107
Series Butterfly Valves
| IOM
Pneumatic Connections
Air Requirements (In accordance with DIN/ISO 8573.1)
Min. supply pressure to
actuator
80psi (5.5bar)
Max. supply pressure to
actuator
100psi (6.9bar)
Air connection hose type
1/4" (6mm) Flexible Poly Tubing
Air Fitting Type
1/8"G Swivel Elbow
Solid particle content
Class 3 Quality. Max size of
solid particles per cubic meter
10000 of 0.5µm ˂ d ˂ 1.0µm.
500 of 1.0µm ˂ d ˂ 5.0µm
Water Content
Class 4 Quality. Max dew point
tempe3°C (37.4°F).
Installations at lower
temperature or varying altitudes
my require adjustments
accordingly.
Air Consumption (liters free air)
0.24 x Supply Pressure (bar)
For normally closed (NC) spring return actuators, supply air to the air fitting to open the valve. For normally open (NO) spring
return actuators, supply air to the air fitting to close the valve. For double acting actuators, supply air to the air fitting to open and
close the valve.
NOTE:
if you wish to change the valve from NO to NC or vice versa, follow the disassembly section of this
manual to remove the actuator, then turn the valve disc to the desired fail position and reattach the actuator.