34
CARE AND MAINTENANCE
HYDROSTATIC PUMPS:
Before each use, check to be sure that the cooling fins
of the hydrostatic pumps are clean. Excessive
accumulation of oil, dirt, or trash may cause the pumps
to overheat. NEVER WASH ACROSS TOP OF RESERVOIR
WITH WATER OR STEAM. Fill reservoir as required per
the maintenance schedule listed in this book
HYDROSTAT DRIVE BELT
REPLACEMENT PROCEDURE (continued):
To remove hydrostat pump drive belt:
(The hydrostat pump drive is equipped with a spring
loaded belt take-up)
1.
Raise seat.
2.
Drain radiator.
3.
Remove radiator mounting hardware and hoses.
4.
Remove radiator.
5.
Remove double u-joint flange bolts and remove
double u-joint.
6.
Rotate the spring loaded take-up idler toward the
left hand hydro pump to provide belt slack for
removal.
7.
Remove belt.