background image

                     

         

 

Automatic Industrial Cordless Brushless 

Power Torque Screwdrivers Series

 

    OPERATION AND MAINTENANCE MANUAL 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Rechargeable -TYPE Automatic Brushless Series 

 

                                           

   

                         

 

      KILEWS INDUSTRIAL CO., LTD. 

                                              http://www.kilews.com.tw             

Y2F174A-1-003 

CAUTION!! 

SKC-PTA-BE90/BE120 SERIES ARE ADVANCEMENT IN HIGH TORQUE MOTORS DESIGN.   
TO BE MORE SAFTY, ASSEMBLE THE AUXILIARY HANDLE BEFORE OPERATION.

 

SKC-PTA-BE120 
SKC-PTA-BE90 
SKC-PTA-BE50F 
SKC-PTA-BE60 
SKC-PTA-BE35 
SKC-PTA-BE35F 

Summary of Contents for SKC-PTA-BE120

Page 1: ...TYPE Automatic Brushless Series KILEWS INDUSTRIAL CO LTD http www kilews com tw Y2F174A 1 003 CAUTION SKC PTA BE90 BE120 SERIES ARE ADVANCEMENT IN HIGH TORQUE MOTORS DESIGN TO BE MORE SAFTY ASSEMBLE...

Page 2: ...ion manual 6 Do not operate in an explosive atmosphere 2 Observe caution and safety notes 7 Do not disassemble 3 Recyclable 8 Forbid to throw away 4 For indoor use only 5 Do not expose to wet or rain...

Page 3: ...en using the electrical power tool take into account the auxiliary handle or swaist hook is advantage of working conditions On the contrary the purposes of the swaist hook or driver hook is convenient...

Page 4: ...assemble or reassemble the device at will which may result in poor performance or danger of injury the warranty applies only to initial package 3 Do not repair the device with other than genuine KILEW...

Page 5: ...Too slow to install the battery may cause error identification so the beep sound and flash would be continuing In order to function properly re assembling it as below process again Install Battery Ste...

Page 6: ...No Description No Description 1 Trigger Switch 8 Indication light 2 Forward Reverse Lever 9 Torque adjustment ring 3 LED Light 10 Control panel 4 Bit sleeve 11 Wrist strap hole 5 Torque fixing ring 1...

Page 7: ...rrow indicates the screwdriver will be clock wise screwing to tighten things up Vice versa left switch means to release the screw As the diagram showing always set the switch to neutral position when...

Page 8: ...ecrease torque output by turning torque adjustment ring clock wise 0 printed on the torque adjustment ring indicates the minimum torque for setting and 8 for the maximum torque setting Do not turn tor...

Page 9: ...l panel Lock and unlock panel avoid changing settings 2 Auxiliary handle For easier use of the screwdriver there is a handle for assisting purpose Please follow instruction below Warning this power sc...

Page 10: ...n batch complete Slow Start Time RC Slow Start Time Speed Level SP Slow Start Speed Full speed activated when slow start time reached Max Fasten Thread HC Hi Thread max no of fastening threads Min Fas...

Page 11: ...conds to enter setting mode 2 Press Set Select in setting mode to go to next setting 3 When NS triggered press Set Select to unlock Reset Reset Press R to reset factory default setting UP DOWN Up Down...

Page 12: ...ceed HT setting 0 10 sec LS When fastening no of thread is smaller than LS setting it will judge this fastening as double and will not count this fastening 10 NS When fastening error occurred the LCD...

Page 13: ...C max fastening no of thread Step3 When setting completes press S to save settings Settings will be saved after screen flash 2 times 1 If no workpiece and screw were not used during HC setting It will...

Page 14: ...es before Lt setting Red LED Bright 3 short beep sounds Low voltage When voltage lower than 17 5V Buzzer alarm trigger but can still be working Red LED Flicks Continue short beep sound Low voltage Whe...

Page 15: ...he screwdriver completely and set the switch to neutral position It could prevent the user from turning the tool on accidentally 11 During operation the switch has been changed accidentally that the d...

Page 16: ...3 0 4 0mm CAUTION SAVE THE INSTRUCTIONS DO NOT DESTROY Model PTA BE120 PTA BE90 PTA BE50F PTA BE60 PTA BE35 PTA BE35F Input Voltage DC 18V N m 6 12 3 9 2 5 2 6 1 3 5 1 3 5 Torque accuracy 3 Duty cycl...