SERIES 90 SINGLE PRICE TROUBLESHOOTING
Page 36 of 23
REJECTS ALL GOOD COINS
1. Problem:
The coin changer will not accept coins.
Troubleshooting:
A)
Make sure there is product in each column. The sold-out lamps are off.
B)
Follow the arrows from left to right.
C)
1.
Push vend motor switch (motor F) - vend motor cycles.
2.
Push vend motor switch (motor E) - vend motor cycles.
3.
Push vend motor switch (motor D) - vend motor cycles.
4.
Push vend motor switch (motor C) - vend motor does not cycle.
*
The problem is the vend motor switch and by-pass switch on motor C and/or
motor D.
5.
If the problem is not found, continue this procedure through motors B and A.
6.
If the problem is not found, check the vend relay.
7.
If the problem is not found, the last component to check would be the coin
changer.