background image

 
 

1592016100 XV300K GB r.1.0 03.06.2011.doc                                                                          XV300K                                                                                                                                   7/13 

  

8

 

COMMAND TERMINALS 

 

Terminal 

Function 

Description

 

NC 

Relay* contact 

Normally closed 

Relay* contact 

Common ( 1A-250Vac / 3A-30Vdc) 

NO 

Relay* contact 

Normally open 

+10Vdc 

Available supply 

Potentiometer power source

 

(max 50mA) 

0..10 

Analog input 1 

0..10Vdc reference (impedance 10kohm) and pwm (+) 

0V 

Signal ground 

Ground for reference and pwm (-)     

4..20 

Analog input 2 

4..20mA reference (impedance 100ohm) 

 

Ground connection 

Ground for command shielding 

 
* XV308K doesn’t contain relay. 

 

 

 
 
 
 
 
 
 
 
 

XV308K 

L

1

/R

  

P

o

w

e

L

2

/S

 

L

3

/T

 

G

ro

u

n

d

 

G

ro

u

n

d

 

G

ro

u

n

d

 

PWM 5/10V 
  5Vdc open 
10Vdc closed

 

+10Vdc 
0..10Vdc / pwm (+) 
0Vdc pwm (-) 
4..20mA

 

DL1: Allarm Led  
DL2: Supply Led 

 

T3/W  Motor 
T2/V    
T1/U   

 

Summary of Contents for XV300K

Page 1: ...XV300K...

Page 2: ...SPECIFICATIONS OF USE 3 3 CODES MODELS 4 4 TECHNICAL SPECIFICATIONS 4 5 STANDARD REFERENCES 5 6 MECHANICAL INSTALLATION 5 7 ELECTRICAL INSTALLATIONS 6 8 COMMAND TERMINALS 7 9 TYPICAL CONNECTIONS BETW...

Page 3: ...technical specifications printed on the label correspond to those on the order form see page coding The regulator is guaranteed for up to 12 months on delivery The guarantee covers production defects...

Page 4: ...cycle amplitude 5 or 10Vdc DIGITAL OUTPUTS Emergency relay 1A 250Vac 3A 30Vdc Not for XV308K ANALOG OUTPUT 10Vdc max load 50mA OPERATING TEMPERATURE 10 CT50 C 14T122 F 20 C 4 F when the power is maint...

Page 5: ...current harmonics filter and it may cause interference in which case the user may be required to take adequate measures with refer at EN 61000 2 4 and EN 61000 3 12 6 MECHANICAL INSTALLATION The XV300...

Page 6: ...rder to prevent the formation of condensation and regular working also cold temperature it is recommended you insure a constant power supply avoiding turning it off continually All connections wires m...

Page 7: ...ntiometer power source max 50mA 0 10 Analog input 1 0 10Vdc reference impedance 10kohm and pwm 0V Signal ground Ground for reference and pwm 4 20 Analog input 2 4 20mA reference impedance 100ohm Groun...

Page 8: ...ay NO relay 10Vdc 0 10Vdc pwm 0Vdc pwm 4 20mA SHIELD L1 R L2 S L3 T GROUD POWER SUPPLY T1 U T2 V T3 W GROUND MOTOR XV312 320K Bridge S6 PWM 5 10V 5V OPEN 10V CLOSE DL1 Supply Led DL2 Alarm Led DL3 Rel...

Page 9: ...1 U T2 V T3 W L3 T L2 S L1 R COMMANDS NC relay COM relay NO relay 10Vdc 0 10Vdc pwm 0Vdc pwm 4 20 mA SHIELD DL1 Led Relay ON DL2 Led Alarm DL3 Led Power supply Bridge S3 PWM 5 10V 5V open 10V closed X...

Page 10: ...s in order to have further information about parameters programming NOTE please pay attention to the wirings 9 1 iCHILL family If you are using a controller of the iCHILL family such as the IC110CX th...

Page 11: ...nection with PWM signal Connection with 0 10V signal 9 2 iPRO family If you are using a controller of the IPRO series it is possible to use a 4 20mA or a 0 10VDC signal command NOTE it is not possible...

Page 12: ...1592016100 XV300K GB r 1 0 03 06 2011 doc XV300K 12 13 Connection with 0 10V signal Connection with 4 20mA signal...

Page 13: ...gnal command to control a XV300K Follows am example of such connections Connection with 4 20mA signal Connection with 0 10V signal 9 4 XC645CX In this case it is possible to use both 4 20mA or 0 10V s...

Reviews: