XR40C – XR40D

4/4

PTC probe: 

-50÷150°C (-58÷302°F)

Resolution: 

0,1 °C or 1°C or 1 °F (selectable).

Accuracy (ambient temp. 25°C)

:  ±0,7 °C ±1 digit

14. CONNECTIONS

14.1  XR40C: 8A COMPRESSOR

N.C.

1 2 3 4 5

6

7

9 10 11 12

Comp

Def

Ev

ap

.

Ro

om

8

Hot Key

8(3)A250V

8(3)A250V

Line

12Vac/dc supply

: connect to the terminals 7 and 8.

24Vac/dc supply

: connect to the terminals 7 and 8.

120Vac supply

: connect to the terminals 7 and 8.

14.2  XR40C: 20A COMPRESSOR

N.C.

1 2 3 4 5

6

7

9 10 11 12

Comp

Def

Ev

ap

.

Ro

om

8

Hot Key

8(3)A250V

20(8)A250V

Line

12Vac/dc supply

: connect to the terminals 7 and 8.

24Vac/dc supply

: connect to the terminals 7 and 8.

120Vac supply

: connect to the terminals 7 and 8.

14.3  XR40D: 8A COMPRESSOR

Line

   3  4

5 6 

8(3)A/250Vac

8(3)A/250Vac

13 14 15 16 17 18 19 

Comp

n.c.

11 12

n.c.

Power 

Supply

HO

T KE

Y

 

 1 2

24Vac/dc supply

: connect to the terminals 11 and 12.

120Vac supply

: connect to the terminals 11 and 12.

230Vac supply

: connect to the terminals 11 and 12.

14.4  XR40D: 20A COMPRESSOR

 

 3 4

5 6 

11 12

Line

8(3)A/250Vac

20(8)A/250Vac

 15 16 17 18 19 

Comp

n.c.

Power 

Supply

HO

T K

EY

 

 1 2

24Vac/dc supply

: connect to the terminals 11 and 12.

120Vac supply

: connect to the terminals 11 and 12.

230Vac supply

: connect to the terminals 11 and 12.

15.  DEFAULT SETTING VALUES

Label

Name

Range

°C/°F

Set

Set point

LS÷US

-5/0

Hy

Differential

0,1

÷

25.5°C/ 1

÷

 255°F

2/4

LS

Minimum set point

-50°C

÷

SET/-58°F

÷

SET

-50/-58

US

Maximum set point

SET

÷

110°C/ SET 

÷

 230°F

110/230

Ot

Thermostat probe calibration

-12

÷

12°C /-120

÷

120°F

0

P2P

Evaporator probe presence

n=not present; Y=pres.

y

OE

Evaporator probe calibration

-12

÷

12°C /-120

÷

120°F

0

OdS

Outputs delay at start up

0÷255 min

0

AC

Anti-short cycle delay

÷

 50 min

1

CCt

Continuos cycle duration

0.0÷24.0h

0.0

COn

Compressor ON time with faulty
probe

÷

 255 min

15

COF

Compressor OFF time with faulty
probe

÷

 255 min

30

CF

Temperature measurement unit

°C 

÷

 °F

°C/°F

rES

Resolution

in=integer; dE= dec.point

dE/-

Lod

Probe displayed

P1;P2

P1

tdF

Defrost type

EL=el. heater;  in= hot gas

EL

dtE

Defrost termination temperature

-50 

÷

 50 °C

8/46

IdF

Interval between defrost cycles

÷

 120 ore

6

MdF

(Maximum) length for defrost

÷

 255 min

30

dSd

Start defrost delay

0÷99min

0

dFd

Displaying during defrost

rt, it, SEt, DEF

it

dAd

MAX display delay after defrost

0 ÷ 255 min

30

Fdt

Draining time

0÷120 min

0

dPo

First defrost after startup

n=after IdF; y=immed.

n

dAF

Defrost delay after fast freezing

0 ÷ 23h e 50’

0.0

ALc

Temperat. alarms configuration

rE= related to set;

Ab = absolute

Ab

ALU

MAXIMUM temperature alarm

Set

÷

110.0°C; Set÷230°F

110/230

ALL

Minimum temperature alarm

-50.0°C

÷

Set/ -58°F

÷

Set

-50/-58

ALd

Temperature alarm delay

÷

 255 min

15

dAO

Delay of temperature alarm at
start up

÷

 23h e 50’

1.30

i1P

Digital input polarity

oP=opening;CL=closing

CL

i1F

Digital input configuration

EAL=extern. alarm; bAL=lock

regulation; PAL=press. switch;
dor=door switch; dEF=defrost;

LHt=disabled; Htr = Cooling -

heating

EAL

did

Digital input alarm delay

0÷255min

5

Nps

Number of activation of pressure
switch

0 ÷15

15

odc

Compressor status with open
door:

no, Fan = normal;

CPr; F_C = Compr. OFF;

no

PbC

Kind of probe

Ptc; ntc

ntc/Ptc

dP1

Room probe display

--

--

dP2

Evaporator probe display

--

--

rEL

Software release

--

4.0

Ptb

Map code

--

-

Hidden parameters

Dixell S.p.A.  Z.I. Via dell’Industria, 27
32010 Pieve d’Alpago (BL) ITALY
tel. +39 - 0437 - 98 33  -  fax +39 - 0437 - 98 93 13

E-mail: [email protected] - http://www.dixell.com