background image

 

,QVWDOOLQJDQG2SHUDWLQJ,QVWUXFWLRQV

Digital controller with off cycle defrost

XR30C

CONTENTS
1.

GENERAL WARNING___________________________________________ 1

2.

GENERAL DESCRIPTION _______________________________________ 1

3.

CONTROLLING LOADS _________________________________________ 1

4.

FRONT PANEL COMMANDS_____________________________________ 1

5.

TEMPERATURE ALARM AND ITS DURATION RECORDING (HACCP) ___ 1

6.

MAIN FUNCTIONS _____________________________________________ 1

7.

PARAMETERS ________________________________________________ 2

8.

DIGITAL INPUT________________________________________________ 2

9.

INSTALLATION AND MOUNTING _________________________________ 3

10. ELECTRICAL CONNECTIONS ___________________________________ 3
11. HOW TO USE THE HOT KEY ____________________________________ 3
12. ALARM SIGNALS ______________________________________________ 3
13. TECHNICAL DATA _____________________________________________ 3
14. CONNECTIONS _______________________________________________ 4
15. DEFAULT SETTING VALUES ____________________________________ 4

1. GENERAL 

WARNING

1.1  PLEASE READ BEFORE USING THIS MANUAL

 

This manual is part of the product and should be kept near the instrument for
easy and quick reference.

 

The instrument shall not be used for purposes different from those described
hereunder. It cannot be used as a safety device.

 

Check the application limits before proceeding.

1.2 

SAFETY PRECAUTIONS

 

Check the supply voltage is correct before connecting the instrument.

 

Do not expose to water or moisture: use the controller only within the operating
limits avoiding sudden temperature changes with high atmospheric humidity to
prevent  formation of condensation

 

Warning: disconnect all electrical connections before any kind of maintenance.

 

Fit the probe where it is not accessible by the End User. The instrument must
not be opened.

 

In case of failure or faulty operation send the instrument back to the distributor
or to “Dixell s.r.l.” (see address) with a detailed description of the fault.

 

Consider the maximum current which can be applied to each relay (see
Technical Data).

 

Ensure that the wires for probes, loads and the power supply are separated
and far enough from each other, without crossing or intertwining.

 

In case of applications in industrial environments, the use of mains filters (our
mod. FT1) in parallel with inductive loads could be useful.

2. GENERAL 

DESCRIPTION

Model  XR30C, format 32 x 74 mm,  is a digital termostat with off cycle defrost
designed for refrigeration applications at normal temperature. It provides two relay
outputs, one for the compressor, the other one can be used for alarm signalling or
as auxiliary output. The probe input can be selected between PTC or NTC. The
instrument has a digital input, for alarm signalling, for switching the auxiliary output
or for start a defrost cycle.

3. CONTROLLING 

LOADS

3.1 COMPRESSOR

The regulation is performed according to the temperature measured by the
thermostat probe with a positive differential from the set point: if the temperature
increases and reaches set point plus differential the compressor is started and then
turned off when the temperature reaches the set point value again.

In case of fault in the thermostat probe the start and stop of the compressor are
timed through parameters “COn” and “COF”.

3.2 DEFROST

Defrost is performed through a simple stop of the compressor. Parameter “IdF
controls the interval between defrost cycles, while its length is controlled by
parameter “MdF”.

4.  FRONT PANEL COMMANDS

SET: To display target set point; in programming mode it  selects a parameter  or

confirm an operation.

(DEF) To start a manual defrost

'

'

(UP): To see the last temperature alarm happened; in programming mode it

browses the parameter codes or increases the displayed value.

&

&

 (DOWN) To see the last temperature alarm happened; hold pressed it switches

the auxiliary output; in programming mode it browses the parameter codes or
decreases the displayed value.

KEY COMBINATIONS:

'

'

+

&

&

 

To lock & unlock the keyboard.

SET +

&

&

To enter in programming mode.

SET + 

'

'

To return to the room temperature display.

4.1  USE OF LEDS

Each LED function is described in the following table.

LED MODE

FUNCTION

ON

Compressor enabled

Flashing -Programming Phase (flashing with 

)

- Anti-short cycle delay enabled

ON

Defrost enabled

Flashing - Programming Phase (flashing with 

)

$8;

ON

Second relay ON

ON

An temperature alarm happened

5.  TEMPERATURE ALARM AND ITS DURATION
RECORDING (HACCP)

XR30C signals and records temperature alarms, together with their duration and
max value reached. See drawing:

Ex. High temperature alarm

S e t

A Lu

H igh te m p. alarm

Tim e

Tem p era ture

A LL

Low  te mp . alarm

;

;

;

A larm  duration

M ax

Tem p era tu re

Safe food zone

5.1  HOW TO SEE THE ALARM DURATION AND MAX (MIN)
TEMPERATURE

If the alarm LED is on, an alarm has taken place.
To see the kind of alarm, the max (min) reached temperature and alarm duration do
as follows:
1. 

Push the Up or Down key.

2. 

On the display the following message is shown::

HAL” for high temperature alarm (“LAL” fot the minimum allarm), followed by
the Maximum (minimum) temperature.
Then the “tiM” (tiMe) message is displayed, followed by the “Duration”  in
h.mm.

3. 

Then the instrument displays the temperature once again.

NOTE1: if an alarm is still occurring the “tim” shows the partial duration.
NOTE2: the alarm is recorded when the temperature come back to normal values

5.2  HOW TO RESET A RECORDED ALARM OR ONE THAT IS
STILL OCCURRING

1.  Hold the SET key pressed for more than 3s, while the recorded alarm is

displayed. (the rSt message will be displayed)

2.  To confirm the operation, the “rSt” message starts blinking and the normal

temperature will be displayed.

6. MAIN 

FUNCTIONS

6.1  HOW TO SEE THE SETPOINT

1.  Push and immediately release the SET key: the display will

show the Set point value;

2.  Push and immediately release the SET key or wait for 5 seconds to display the

probe value again.

Reviews: