![dixell Wing XW35L Installing And Operating Instructions Download Page 4](http://html1.mh-extra.com/html/dixell/wing-xw35l/wing-xw35l_installing-and-operating-instructions_2511067004.webp)
,QVWDOOLQJ DQG 2SHUDWLQJ ,QVWUXFWLRQV
vwxyz y{|} ~yz{{
vwxyz y{|} ~yz !{{"
1592009275 XW35L 8-40vdc GB r1.0 19.10.2004.doc
% )
4/4
Power absorption: 7VA max.
Display: 3 digits, red LED, 14,2 mm high.
Inputs: 1 NTC or PTC probe
Digital input: 1 free voltage
Relay outputs:
compressor: relay SPST 8(3) A, 250Vac
light: XW35L: relay SPDT 8(3) A, 250Vac;
fans: relay SPST 8(3) A, 250Vac
Other output : alarm buzzer (optional)
Data storing: on the non-volatile memory (EEPROM).
Kind of action: 1B.
Pollution grade: normal
Software class: A.
Operating temperature: 0÷60 °C.
Storage temperature: -25÷60 °C.
Relative humidity: 20
÷
85% (no condensing)
Measuring and regulation range:
PTC probe: -50÷150°C (-58÷302°F)
NTC probe: -40÷110°C (-58÷230°F)
Resolution: 0,1 °C or 1°C or 1 °F (selectable).
Accuracy (ambient temp. 25°C): ±0,5 °C ±1 digit
12.
CONNECTIONS
12.1
XW35L
Ro
om
Di
gi
t.
Inp
.
Comp
8(3)A
250V
¡
¢
8(3)A
250V
N.C.
Light
N.C.
8(3)A
250V
C.
C.
C.
Fan
13.
DEFAULT SETTING VALUES
Label Name
Range
Default
Level
REGULATION
Set
Set point
LS÷US
3
Pr1
Hy
Differential
0,1÷25,5 °C / 1÷45°F
2
Pr1
LS
Minimum set point
-50,0°C÷SET / -58°F÷SET
-10
Pr2
US
Maximum set point
SET ÷ 110°C / SET ÷
230°F
20
Pr2
OdS
Outputs activation delay at start up
0÷255 min.
0
Pr2
AC
Anti-short cycle delay
0÷30 min.
1
Pr1
CCt
Compressor ON time during fast freezing
0 ÷ 23h 50 min.
0.0
Pr2
COn
Compressor ON time with faulty probe
0÷255 min.
15
Pr2
COF
Compressor OFF time with faulty probe
0÷255 min.
30
Pr2
CH
Type of regulation
CL, Ht
CL
Pr2
DISPLAY
CF
Temperature measurement unit
°C ÷ °F
°C
Pr2
rES
Resolution (integer/decimal point)
in ÷ de
dE
Pr1
DEFROST
EdF
Defrost mode
In, Sd
in
Pr2
IdF
Interval between defrost cycles
1÷120h
8
Pr1
MdF
(Maximum) length for 1° defrost
0÷255 min.
20
Pr1
dFd
Displaying during defrost
rt, it, SEt, dEF, dEG
it
Pr2
dAd
MAX display delay after defrost
0÷255 min.
30
Pr2
dPO
First defrost after start up
n ÷ y
n
Pr2
dAF
Defrost delay after fast freezing
0 ÷ 23h 50 min.
0.0
Pr2
FANS
FnC
Fans operating mode
C-n, C-y, O-n, O-y
o-y
Pr2
Fnd
Fans delay after defrost
0÷255 min.
0
Pr2
FSt
Fans stop temperature
-50,0÷110°C/ -58÷230°F
80
Pr2
ALARMS
ALC
Temperature alarms configuration
rE÷Ab
Ab
Pr2
ALU
MAXIMUM temperature alarm
-50,0÷110°C/ -58÷230°F
110
Pr1
ALL
minimum temperature alarm
-50,0÷110°C/ -58÷230°F
-40
Pr1
AFH
Temperature alarm differential
0,1÷25,5 °C / 1÷45°F
2
Pr2
ALd
Temperature alarm delay
0÷255 min.
15
Pr2
dAO
Delay of temperature alarm at start up
0 ÷ 23h 50 min.
1,3
Pr2
EdA
Alarm delay at the end of defrost
0÷255 min.
30
Pr2
dot
Delay of temperature alarm after closing the
door
0÷255 min.
15
Pr2
dOA
Open door alarm delay
0÷255 min.
15
Pr2
tbA
Abilitazione tacitazione relè allarme
n, y
y
Pr2
nPS
Pressure switch number
0÷15
0
Pr2
ANALOGUE INPUTS
Ot
Thermostat probe calibration
-12,0÷12,0°C / -21÷21°F
0
Pr1
HES
Temperature increasing during the Energy
Saving cycle
-30÷30°F/-54÷54°F
0
Pr2
DIGITAL INPUTS
Odc
Open door control
no, Fan, CPr, F_C
no
Pr2
I2P
Configurable digital input polarity
CL÷OP
CL
Pr2
i2F
Digital input configuration
dor, EAL, bAL, PAL, dFr,
AUS, ES, OnF
dor
Pr2
dId
Digital input alarm delay
0÷255 min.
5
Pr2
OTHER
Pbc
Kind of probe
PbC, ntc
ntc/Ptc
Pr2
rEL
Software release
- - -
2.0
Pr2
Ptb
Map code
- - -
- - -
Pr2
Prd
Probes display
Pb1
- - -
Pr2
Pr2
Access parameter list
- - -
- - -
Pr1
Dixell S.p.A. Via dell’Industria, 27
32010 Z.I Pieve d’Alpago (BL) ITALY
tel. +39 - 0437 - 98 33 - fax +39 - 0437 - 98 93 13
£¥¤§¦©¨ª
«
¬
%ª
®°¯«
«
±²ª
®°¯«
«
³
´¶µ ¦·¤¹¸»º
º
¼¬
½¾½¿R¿R¿À³
%ª
®°¯«
«
³
´¶µ ¦