dixell Wing XW35L Installing And Operating Instructions Download Page 4

,QVWDOOLQJ DQG 2SHUDWLQJ ,QVWUXFWLRQV

vwxyz y{|} ~yz€‚{{‚ƒ€

vwxyz y{|} ~yz €!‚{{"‚ƒ€

1592009275  XW35L 8-40vdc GB r1.0 19.10.2004.doc

                           

„%…†‡)ˆ

4/4

Power absorption: 7VA max.

Display: 3 digits, red LED, 14,2 mm high.

Inputs: 1 NTC or PTC probe

Digital input: 1 free voltage

Relay outputs:

compressor: relay SPST 8(3) A, 250Vac

light: XW35L: relay SPDT 8(3) A, 250Vac;

fans: relay SPST 8(3) A, 250Vac

Other output : alarm buzzer (optional)

Data storing: on the non-volatile memory (EEPROM).

Kind of action: 1B.

Pollution grade: normal

Software class: A.

Operating temperature: 0÷60 °C.

Storage temperature: -25÷60 °C.

Relative humidity: 20

÷

85% (no condensing)

Measuring and regulation range:

PTC probe: -50÷150°C (-58÷302°F)

NTC probe: -40÷110°C (-58÷230°F)

Resolution: 0,1 °C or 1°C or 1 °F (selectable).

Accuracy (ambient temp. 25°C):  ±0,5 °C ±1 digit

12.

 

CONNECTIONS

12.1

 

XW35L

Ro

om

‰‰

Š

‹Œ

Ž



‘“’

”•

–˜—

–™

Di

gi

t. 

Inp

.

Comp

š

›

œ

8(3)A

250V



žŸ

ž 

¡

ž

¢

8(3)A

250V



N.C.

Light

N.C.

8(3)A

250V



C.

C.

C.

Fan

13.

 

DEFAULT SETTING VALUES

Label Name

  Range

Default

Level

REGULATION

Set

Set point

LS÷US

3

Pr1

Hy

Differential

0,1÷25,5 °C / 1÷45°F

2

Pr1

LS

Minimum set point

 -50,0°C÷SET / -58°F÷SET

-10

Pr2

US

Maximum set point

SET ÷ 110°C / SET ÷

230°F

20

Pr2

OdS

Outputs activation delay at start up

0÷255 min.

0

Pr2

AC

Anti-short cycle delay

0÷30 min.

1

Pr1

CCt

Compressor ON time during fast freezing

0 ÷ 23h 50 min.

0.0

Pr2

COn

Compressor ON time with faulty probe

0÷255 min.

15

Pr2

COF

Compressor OFF time with faulty probe

0÷255 min.

30

Pr2

CH

Type of regulation

CL, Ht

CL

Pr2

DISPLAY

CF

Temperature measurement unit

°C ÷ °F

°C

Pr2

rES

Resolution (integer/decimal point)

in ÷ de

dE

Pr1

DEFROST

EdF

Defrost mode

In, Sd

in

Pr2

IdF

Interval between defrost cycles

1÷120h

8

Pr1

MdF

(Maximum) length for 1° defrost

0÷255 min.

20

Pr1

dFd

Displaying during defrost

rt, it, SEt, dEF, dEG

it

Pr2

dAd

MAX display delay after defrost

0÷255 min.

30

Pr2

dPO

First defrost after start up

n ÷ y

n

Pr2

dAF

Defrost delay after fast freezing

0 ÷ 23h 50 min.

0.0

Pr2

FANS

FnC

Fans operating mode

C-n, C-y, O-n, O-y

o-y

Pr2

Fnd

Fans delay after defrost

0÷255 min.

0

Pr2

FSt

Fans stop temperature

-50,0÷110°C/ -58÷230°F

80

Pr2

ALARMS

ALC

Temperature alarms configuration

rE÷Ab

Ab

Pr2

ALU

MAXIMUM temperature alarm

-50,0÷110°C/ -58÷230°F

110

Pr1

ALL

minimum temperature alarm

-50,0÷110°C/ -58÷230°F

-40

Pr1

AFH

Temperature alarm differential

0,1÷25,5 °C / 1÷45°F

2

Pr2

ALd

Temperature alarm delay

0÷255 min.

15

Pr2

dAO

Delay of temperature alarm at start up

0 ÷ 23h 50 min.

1,3

Pr2

EdA

Alarm delay at the end of defrost

0÷255 min.

30

Pr2

dot

Delay of temperature alarm after closing the

door

0÷255 min.

15

Pr2

dOA

Open door alarm delay

0÷255 min.

15

Pr2

tbA

Abilitazione tacitazione relè allarme

n, y

y

Pr2

nPS

Pressure switch number

0÷15

0

Pr2

ANALOGUE INPUTS

Ot

Thermostat probe calibration

-12,0÷12,0°C / -21÷21°F

0

Pr1

HES

Temperature increasing during the Energy

Saving cycle

-30÷30°F/-54÷54°F

0

Pr2

DIGITAL INPUTS

Odc

Open door control

no, Fan, CPr, F_C

no

Pr2

I2P

Configurable digital input polarity

CL÷OP

CL

Pr2

i2F

Digital input configuration

dor, EAL, bAL, PAL, dFr,

AUS, ES, OnF

dor

Pr2

dId

Digital input alarm delay

0÷255 min.

5

Pr2

OTHER

Pbc

Kind of probe

PbC, ntc

ntc/Ptc

Pr2

rEL

Software release

- - -

2.0

Pr2

Ptb

Map code

- - -

- - -

Pr2

Prd

Probes display

Pb1

- - -

Pr2

Pr2

Access parameter list

- - -

- - -

Pr1

Dixell S.p.A. Via dell’Industria, 27

32010 Z.I Pieve d’Alpago (BL) ITALY

tel. +39 - 0437 - 98 33 - fax +39 - 0437 - 98 93 13