ALARM RECOVERY 

Probe alarm: “P1” (probe1 faulty), automatically stops 10s after the probe restarts normal operation. 
Check connections before replacing the probe. 
Temperature alarms “HA” and “LA” automatically stop as soon as the thermostat temperature returns 
to normal values. 
Door switch alarm “dA”  stop as soon as the door is closed. 
External alarms “EAL”, “BAL”  stop as soon as the external digital input is disabled  
Pressure switch alarm PAL” alarm is recovered by switching OFF the instrument

11.

 

TECHNICAL DATA 

Housing: self extinguishing ABS. 

Case 
 XW10L: 

facia 38x185 mm; depth 76mm 

 XW10V: 

facia 100x64 mm; depth 76mm 

Mounting  

XW10L: panel mounting in a 150x31 mm panel cut-out with two screws. 

 3 x 2mm. Distance 

between the holes 165mm 
XW10L: panel mounting in a 56x72 mm panel cut-out with two screws. 

 3x2mm. Distance 

between the holes 40mm 

Protection: IP20. 
Frontal protection:
 IP65 with optional frontal gasket mod  RG-L (XW40L); RGW-V (XW40V). 
Connections: Screw terminal block 

 2,5 mm

2

 heat-resistant wiring and 6,3mm Faston 

Power supply: 230Vac or. 110Vac 

±

 10%  

Power absorption: 7VA max. 
Display
: 3 digits, red LED, 14,2 mm high.  
Inputs: 1 NTC or PTC probe 
Digital input: 1 free voltage 

Relay outputs: Total current on loads MAX. 20A 

compressor: relay SPST 20(8) A, 250Vac or. SPST 8(3) A, 250Vac 
light: XW10L: relè SPDT 8(3) A, 250Vac; XW10V: relè SPST 16(6) A, 250Vac 

Other output : alarm buzzer (optional) 
Data storing: on the non-volatile memory (EEPROM). 
Kind of action: 1B. 
Pollution grade: normal 
Software class: A. 
Operating temperature: 
0÷60 °C. 
Storage temperature: -25÷60 °C.  
Relative humidity: 20

÷

85% (no condensing) 

Measuring and regulation range:  

PTC probe: -50÷150°C (-58÷302°F) 
NTC probe: -40÷110°C (-58÷230°F) 

Resolution: 0,1 °C or 1°C or 1 °F (selectable). 
Accuracy (ambient temp. 25°C):  ±0,5 °C ±1 digit 

 

12.

 

CONNECTIONS 

Room

Probe

XW10V

Comp

Line

Ne

ut

ra

l

Light

19

12

5 6 7 8 9 10 11

2 3 4

17 18

20 21

Digital 

Input

20A

250Vac

MAX

20A

16A

250Vac

 

 

Di

gi

ta

l i

np

Room

Probe

XW10L

20A

250Vac

MAX

20A

Comp

Li

ne

Ne

ut

ra

l

8A

250Vac

13 14 15 16

12

5 6 7 8 9 10 11

1 2 3 4

17

Luce

 

 

 

13.

 

DEFAULT SETTING VALUES 

 

Label  Name 

  Range 

Default  Level 

  REGULATION  

°C/°F 

 

Set Set 

point 

LS÷US 

5/41  Pr1 

Hy 

Differential 

0,1÷25,5 °C / 1÷45°F 

2/4 

Pr1 

LS 

Minimum set point 

 -50,0°C÷SET / -58°F÷SET  -50/-58 Pr2 

US 

Maximum set point 

SET ÷ 110°C / SET ÷ 

230°F 

110/230 

Pr2 

OdS 

Outputs activation delay at start up 

0÷255 min. 

Pr2 

AC 

Anti-short cycle delay 

0÷30 min. 

Pr1 

CCt 

Compressor ON time during fast freezing 

0 ÷ 23h 50 min. 

0.0 

Pr2 

COn 

Compressor ON time with faulty probe 

0÷255 min. 

15 

Pr2 

COF 

Compressor OFF time with faulty probe 

0÷255 min. 

30 

Pr2 

CH 

Type of regulation 

CL, Ht 

CL 

Pr2 

 DISPLAY 

 

 

 

CF 

Temperature measurement unit 

°C ÷ °F 

°C/F 

Pr2 

rES 

Resolution (integer/decimal point) 

in ÷ de 

dE/- 

Pr1 

 ALARMS 

 

 

 

ALC 

Temperature alarms configuration rE÷Ab 

Ab 

Pr2 

ALU 

MAXIMUM temperature alarm -50,0÷110°C/ 

-58÷230°F 

110/230 

Pr1 

ALL 

minimum temperature alarm 

-50,0÷110°C/ -58÷230°F  -40/-40 

Pr1 

AFH 

Temperature alarm differential 

0,1÷25,5 °C / 1÷45°F 

2/4 

Pr2 

ALd 

Temperature alarm delay 

0÷255 min. 

15 

Pr2 

dAO 

Delay of temperature alarm at start up 

0 ÷ 23h 50 min. 

1,3 

Pr2 

dot 

Delay of temperature alarm after closing the 
door  

0÷255 min. 

15 

Pr2 

dOA 

Open door alarm delay  

0÷255 min. 

15 

Pr2 

nPS 

Pressure switch number 

0÷15 

Pr2 

 ANALOGUE 

INPUTS 

 

 

 

Ot 

Thermostat probe calibration 

-12,0÷12,0°C / -21÷21°F 

0/0 

Pr1 

HES Temperature 

increasing during the Energy 

Saving cycle 

-30÷30°F/-54÷54°F 0/0 Pr2 

  DIGITAL INPUTS 

 

 

 

Odc 

Open door control  

no, Fan, CPr, F_C 

no 

Pr2 

I2P 

Configurable digital input polarity 

CL÷OP 

CL 

Pr2 

i2F 

Digital input configuration 

dor, EAL, bAL, PAL, dFr,  

AUS, ES, OnF 

dor Pr2 

dId 

Digital input alarm delay 

0÷255 min. 

Pr2 

  OTHER  

 

 

Pbc 

Kind of probe 

PbC, ntc 

ntc/Ptc 

Pr2 

rEL 

Software release 

- - - 

2.0 

Pr2 

Ptb 

Map code 

- - - 

- - - 

Pr2 

Prd 

Probes display 

Pb1 

- - - 

Pr2 

Pr2  

Access parameter list 

- - - 

- - - 

Pr1 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for Wing Series

Page 1: ...fferential the compressor is started and then turned off when the temperature reaches the set point value again In case of fault in the thermostat probe the start and stop of the compressor are timed through parameters COn and COF 3 3 CH HT HEATING APPLICATION The Hy value is automatically set under the Set Point If the temperature decreases and reaches set point minus differential the regulation ...

Page 2: ...C Ab ALL 110 C or 230 F when this temperature is reached and after the ALd delay time the HA alarm is enabled ALL Low temperature alarm setting ALC rE 0 50 C or 90 F ALC Ab 50 C or 58 F ALU when this temperature is reached and after the ALd delay time the LA alarm is enabled AFH Temperature alarm differential 0 1 25 5 C 1 45 F Intervention differential for temperature alarm set point always positi...

Page 3: ...ove the TTL serial cable if present insert the Hot Key and then turn the Wing ON 2 Automatically the parameter list of the Hot Key is downloaded into the Wing memory the DoL message is blinking After 10 seconds the instrument will restart working with the new parameters 3 Turn OFF the instrument remove the Hot Key plug in the TTL serial cable then turn it ON again At the end of the data transfer p...

Page 4: ...1 digit 12 CONNECTIONS Room Probe XW10V Comp Line Neutral Light 19 12 5 6 7 8 9 10 11 2 3 4 17 18 20 21 Digital Input 20A 250Vac MAX 20A 16A 250Vac Digital inp Room Probe XW10L 20A 250Vac MAX 20A Comp Line Neutral 8A 250Vac 13 1415 16 12 5 6 7 8 9 10 11 1 2 3 4 17 Luce 13 DEFAULT SETTING VALUES Label Name Range Default Level REGULATION C F Set Set point LS US 5 41 Pr1 Hy Differential 0 1 25 5 C 1 ...

Reviews: