Frecuency Manual Reference
Pre-Use
• Perform pre-use inspection to ensure operating correctly. 4.3
ISC-360 Self-Cleaning Cycle
• Automatically initiated each time unit is turned OFF. 4.5
Every (1) Week - Empty Dust Drawer
• Remove dust drawer and deposit accumulated particulate in appropriate waste container. Refer to local regulations
regarding disposal procedures as some captured contaminants may be flammable, explosive, or toxic.
• Recommended frequency is one week, but may be less or more depending of application.
As Required – Replace Filter
1. Replace Filter
Every (12) months Inspect Basic Components
1. Clean unreadable labels and exterior surfaces
2. Capture Arm: Check for tears in flex hoses and fitting of hose clamps
3. Cabinet: Look for loose wiring.
4. ICS-360 Function Test:
• Open Cabinet Door (keep open)
• Remove Filter
• Turn ON unit, and then OFF
• Observe if ICS-360 cycle initiates (normal delay of 30 seconds)
• Observe if air nozzle passes the complete range (bottom-to-top) of acme shaft.
11
5.3 Routine Maintenance Schedule
The manufacturer recommends the following routine maintenance based on light-duty use in normal operating conditions. Service more frequently if the
unit is used in severe conditions.