Tunnel   Shu:ers®   come   in   4   foot   wide   modular   units   that   connect   together   allowing   a   

conRnuous   run   of   Shu:ers   for   any   required   lengths.      The   modular   units   can   be   divided   into   as   many   
“secRonal   groups”   as   desired.      An   addiRonal   Gear/Motor   machine   will   be   required   for   each   secRon   or   

group   of   Shu:er   units.      Currently   the   only   machine   authorized   for   use   with   Tunnel   Shu:ers®   is   the   

Di   

Drive   

by   Diversified.   

   

Required   Materials:      

   Straight   Pressure   treated   2x4s   (equal   to   length   of   Tunnel   openings)   

                                                                                                                     Heavy   nails   or   deck   screws   to   install   support   2x4s,   and   Silicone   Caulking.      

   

Required   Tools:   

   Cordless   Drills   with   1/2”   and   9/16”   nut   drivers,   2   _   Carpenters   Square,   3   _   Level,   Allen   

Wrenches   (4mm),   Sockets/Wrenches   for   5/16,   3/8,   7/16,   9/16,   and   17mm   bolt/nut   heads,   Marker   pen,   

tape   measure,   and   a   hammer.      Work   bench   or   Saw   horses.         Also   required   is   a   “Z”   square   tool   for   easy   
installaRon   of   the   torque   tube   support   brackets   when   installing   in   doghouses.      This   simple   tool   will   be   

provided   with   each   shipment   of   Tunnel   Shu:ers.         You   will   not   require   the   “Z”   tool   if   you   are   using   the   

“Hangers”   for   the   torque   tube   supports.      
   

   

4.

Framing   Specifica$ons   

      

   

   

Shu:er   units   can   cover   window/tunnel   openings   with   heights   of   4   to   6   feet   high   and   run   

for   any   required   length   of   opening   as   required.      The   individual   Shu:er   units   are   exactly   4   feet   wide   on   

center,   so   the   total   length   of   the   window/tunnel   opening   should   equal   a   distance   that   is   divisional   by   

4

   

(ex.   16,   40,   88,   100   feet)   and   then   subtract   2   inches   from   this   length.      

   The   wall   studs   of   should   be   spaced   4   feet   on   center   to   align   with   the   Shu:er’s   “VerRcal   

Rails”   (also   4   feet   on   center)   as   these   rails   require   center   support   behind   them.      However,   houses   with   

Stud   spacing   that   is   not   4   feet   on   center   can   have   a   verRcal

   2x4

   stud   placed   behind   each   shu:er   VerRcal   

Rail.      This   will   provide   the   required   support   behind   the   Shu:er’s   VerRcal   Rails.   The   wall   studs   need   to   be   
flush   with   the   header   and   footer   of   the   window   opening   to   properly   support   the   VerRcal   Rails.      In   most   

cases   this   can   easily   be   done   by   covering   the   wall   Studs   with   the   same   plywood   that   is   on   the   header/
footer   of   the   wall.   

   It   is   also   recommended   that   1   to   2   feet   of   wall   space   area   is   available   at   each   end   of   the   

window/tunnel   opening   to   ensure   clearance   for   the   Di   Drive   machine   and   provide   tolerance   for   the   ends   
of   the   Tunnel   Shu:ers®   secRons   (picture   on   page   7).            

   

4.1                     New   Construc$on   Doghouses   

            

For   construcRon   of   new   houses   it   is   recommended   that   the   Doghouses   have   a   minimum   height   of   8   Ft.   

(inner   wall),   the   Studs   placed   on   4   Ft   centers,   the   tunnel   window   opening   is   no   higher   than   59   inches,   the   
window   opening   is   kept   low   on   the   wall   with   the   bo:om   of   the   window   sill   no   higher   than   12   inches   from   

the   floor,   

and   the   Doghouse   internal   width   is   22   to   28   inches   wide

.      It   is   also   necessary   to   cover   the   

Studs   with   the   same   thickness   of   plywood   so   the   Studs   are   faired   evenly   with   the   Wall   surfaces.               
            It   is   also   recommended   that   the   

chicken   wire   

is   placed   under   the   plywood   of   the   inner   wall      and   Studs   

of   the   Doghouse.   

See   the   drawings   on   the   next   page   (6)   for   new   construc$on   specifica$ons.

   

Summary of Contents for Tunnel Shutters

Page 1: ...Owners Manual Part No 6100001 Installing Tunnel Shu ers Rev 6 17...

Page 2: ...Horizontal Rail 9 5 5 Install Second VerRcal Rail 9 5 6 Hang Shu ers 10 5 7 Install Top Horizontal Rail 10 5 8 A ach Flap Seal 11 5 9 Installing Tie Bars 12 5 10 MounRng Sha_ Support Brackets 12 5 10a...

Page 3: ...ly injury Never enter the Doghouse area unless electrical power has been disconnected from the Tunnel Shu ers Gear motor When powered and opera ng the Shu ers for the rst me ensure they are not raised...

Page 4: ...rs below This limited warranty is expressly in lieu of any and all representaRons and warranRes expressed or implied including any implied warranty of merchantability or tness for a parRcular purpose...

Page 5: ...ional by 4 ex 16 40 88 100 feet and then subtract 2 inches from this length The wall studs of should be spaced 4 feet on center to align with the Shu er s VerRcal Rails also 4 feet on center as these...

Page 6: ...Part No 6100001 Rev 6 17 Installing Tunnel Shu ers Page 6 Please follow the following speci ca ons for construc on If mounRng within a Doghouse...

Page 7: ...ended 75 degree angle opening of the Shu ers For Example A Doghouse that only has a width of 19 inches would require a 1 inch notch cut into the outer 4x4 studs to allow the Shu ers to open to a recom...

Page 8: ...ing Now mark a line under the Bo om Coupler This mark will be the reference line for the top of the wood 2x4 Measure the distance from this line up to the bo om of the window sill and conRnue to mark...

Page 9: ...all coupler and rail joints are ght before screwing down Now run a bead of Caulking clear along the inside edge of the Bo om Horizontal Rail pic 4 5 5 Install Second Ver cal Rail Place a second VerRc...

Page 10: ...anging ap seal a ached to it Note 2 of the Shu ers in each box will need the Hinges and Tie Bracket a ached to the Shu er panels using the provided screws This is to reduce shipping costs and prevent...

Page 11: ...le_ Next install the Retainer strip below the ridge of the seal Fasten the Retainer Strip with screws to the at face of the Top Rail just below its center screw The ends of the Retainer should be pla...

Page 12: ...he Shu er s Top Rail and pushed rmly against the doghouse inner wall With the Square s measurements set to exactly 19 inches out and 11 inches down to the top corner of the Bushing Plate hold at a lev...

Page 13: ...Simply rest the a aching end of the Hanger directly on top of the Top Shu er Rail and drill 4 pilot holes for lag bolts The hanger must be posiRoned so the bolts screw into the frame of the house and...

Page 14: ...to make sure that none of the Sha_ connecRng bolts will be in the way of the Pinion s placement which is directly in line with the Tie Bars Slide the Sha_ as needed to avoid this You may also need to...

Page 15: ...otor end up down or even horizontally if required Take into account that the manual drive connecRon is on the bo om of the motor Therefore the motor would need to be in a posi on where it could be eas...

Page 16: ...The edge of the square should split the channel of the Rack Arm see pic 2 With the Pinion sibng in this posiRon mark both sides of the Pinion onto the sha_ using a permanent marker This will be the e...

Page 17: ...ers will not contact the Hangers It is a good idea for at least two people to watch while the Shu ers are being opened for the rst Rme Do Not open the Shu ers past 90 degrees or high enough to hit the...

Page 18: ...Part No 6100001 Rev 6 17 Installing Tunnel Shu ers Page 18...

Page 19: ...secRon 5 16 Loosen the two set screws of the Shu er unit that is not fully closed you may need to run the motor open a li le to gain access to the screws Fully close the enRre secRon of Shu ers using...

Page 20: ...Part No 6100001 Rev 6 17 Installing Tunnel Shu ers Page 20 Bo om Top 6...

Page 21: ...4 Ft unit overall Height 49 window height 46 max 5 Ft unit overall Height 63 5 window height 60 max 6 Ft unit overall Height 78 window height 74 5 max Note 5 and 6 Units When Shu ers are full open th...

Page 22: ...______________________________________________________ _____________________________________________________________________________ ___________________________________________________________________...

Reviews: