diversey CO350.5 Manual Download Page 8

48

End of operation

Emptying the recovery / solution tank

The disposal of the soiled water or the cleaning solution must be carried out in 
accordance with the appropriate national regulations.
Proceed as follows for both tanks:

Clean the recovery tank

Solution tank

After end of operation

Periodic maintenance

Clean solution tank filter

• Stop the flow of solution.

• Drive a few metres so that the tool rotates further for a short time. You will 

avoid dripping by doing this.

• Allow the suction unit to continue running so that all the remaining water will 

be vacuumed up.

• Release the operating lever.

• Now switch off the suction unit and then the 

machine or switch off the machine directly if the 
suction unit should be immediately switched on 
again the next time the machine is switched on. 
(See page 47: One-Button Function)

All the compoenents that have to be cleaned are marked in 
yellow.
Always drain and clean the recovery tank after using the machine.

If the soiled water is allowed to stand, unpleasant smells and the 

deposition of the dirt will take place after a few hours.

• Switch the machine off.
• Open the tank lid.

• To empty the 

recovery tank

, remove the sieve 

(1), turn the lid (2) to the side, and then lift the 
tank from the machine.

The tank can be completely drained via the 

drainage hole (2). 

• You will have to screw off the filter to empty the 

solution tank

.

• Stop cleaning.

• Switch the machine off.
• Open the tank lid.
• Remove the coarse dirt sieve (yellow), empty and clean it.
• Turn the lid from the drainage hole.

• Remove the 

recovery tank 

and clean it under running water.

The tank can be completely drained via the drainage hole. 

• Replace the recovery tank on the machine.
• Then thoroughly rinse out the solution tank with clean water.
• Check that the float is functioning correctly and that the suction filter (yellow) 

is clean.

In case of damage or soiling of the float and suction filter, please refer to 

page 50.

• Replace the lid of the drainage hole by pressing 

it down.
Ensure that the lid locks into place

.

1

2

3

• Switch the machine off.

1.

Rinse out the 

t

ank well with water only

Fill the solution tank with water. Push the machine to the floor drain or a 
suitable location. Turn the tool unit on and flush out the complete system 
with water.
Then completely drain the solution tank by screwing out the filter.

2.

Cleaning with chlorine tablets

Completely fill the solution tank with clear water. Add the chlorine tablets 
according to the manufacturer's instructions. Switch on the tool unit and 
rinse the complete system witn chlorine solution for approx. 30 seconds. 
Then allow the solution to work in for 45-60 minutes in the solution tank.

3.

Work at the end of operation

Completely drain out the chlorine solution by unscrewing the filter. Then 
screw the filter back into the filter housing. Half-fill the solution tank with 
clean water. Switch on the tool unit and flush out the complete system 
with clean water. Flush out the solution tank well. Drain any remaining 
water out of the solution tank, and then screw the filter back into the filter 
housing. Leave the tank lid open, and allow the solution tank to dry out 
completely.

Do not add any detergent to the chlorine solution, as AOX 
(adsorbiing organic halogen compounds) could arise. These are 
environmentally dangerous and poisonous.

Caution:

Never add chlorine tablets to acid solutions. (development of 
chlorine gas). 

Always instruct your personnel about this!

 Only 

decalcify when necessary, and never use chlorine tablets at the 
same time!

Caution:

Store chlorine tablets at a safe distance from any acidic products. 

Always instruct your personnel about this!

Caution:

Clogged filters reduce the flow of the cleaning solution. As a 
consequence you may damage the floor coating.

• Switch the machine off.

• Once the solution tank has been emptied, screw 

the filter of the solution tank on again.

• Rinse the filter under running water.

The 

filter must be decalcified when necessary.

The filter is lower than the tank outflow. A residual amount of 
solution will flow out once the filter cap has been unscrewed.

• Refit the solution filter.

STOP

Summary of Contents for CO350.5

Page 1: ...swingo 350B V006 12089 70 1137 I25 I24 I23 I22 I21 I20 tr sv pt pl no it fr fi es en de da cz cn 12089 70...

Page 2: ...use this machine in rooms in which explosive and easily inflammable materials such as petrol solvents fuel oil dusts etc are stored or processed The electrical or mechanical components could lead to t...

Page 3: ...ecember 2004 for the harmonisation of the legal regulations of the Member States regarding electro magnetic compatibility and for the annulment of Directive 89 336 EEC Harmonised standards applied EN...

Page 4: ...ne for the electronic lines for the controller 21 Solution tank 22 Holder for the battery charger cable 23 Battery disconnection socket 24 Parking support 25 Locking handle for squeegee 26 Deflection...

Page 5: ...low indicator lights up permanently until approx 90 of the battery capacity has been reached After that the indicator blinks until the battery is fully charged When the charging process is complete th...

Page 6: ...0 5 50ml to 10l water 10l 50ml 0 5l Add the product measured with the dosing cup to the water in the solution tank The TASKI J Flex dosing system or the QFM dosing station can also be used for simplif...

Page 7: ...ase of malfunction see page 50 LED blinks red 2 minutes to conclude the work before the machine switches off automatically LED permanently red Requires a complete charging cycle Pull on the adjusting...

Page 8: ...e hole by pressing it down Ensure that the lid locks into place 1 2 3 Switch the machine off 1 Rinse out the tank well with water only Fill the solution tank with water Push the machine to the floor d...

Page 9: ...ion This will prevent any blockage of the suction hose Switch the machine off Stand the machine on the parking support Open the tank lid Remove the recovery tank 2 1 Remove the hoses from the cover Re...

Page 10: ...napper lugs 2 latch in correctly Caution Danger of injury from clamping the fingers 2 1 2 1 3 Switch the machine off The yellow suction filter can be easily removed quick fit seal Clean it with water...

Page 11: ...s Pull the height adjustment lever and fold the guide pillar towards the front Let go of the height adjustment lever the guide pillar will locate into place and stay at that angle To lift the machine...

Reviews: