![Dive Gear Express XTRA Second Stage Service Manual Download Page 12](http://html1.mh-extra.com/html/dive-gear-express/xtra-second-stage/xtra-second-stage_service-manual_2510479012.webp)
5
.
Second Stage Disassembly
(1) In the following steps, the part numbers from the schematic will be used with their description. Have the
schematic in front of you while following the instructions! Be sure to keep all old parts organized and separate
from new ones in the service kit!
1. Remove the Second Stage from the hose after depressurizing the system. Unscrew the Case Cover (41)
from the Case (11) and remove the Cover (3), Diaphragm Cover (4), and the Diaphragm (06) and Diaphragm
Disc (05) assembly. Fig. 6 This reveals the Valve Spindle Assembly in the case. Fig. 7
Fig. 6 Fig. 7
2. Remove the Retaining Nut (08). Holding the Lever (20) down, slide/pull the Valve Spindle Assembly out of
the case as one unit. Fig. 8
Fig. 8
3. Slide the Venturi Lever (18) off of the spindle while holding down the Lever (20). Be careful after sliding
the Venturi Lever (18) off to allow it to come up slowly. Fig.9
Fig. 9