User Manual
Safe Money automatic safe
13
5.3
COIN FEEDER STATE
Fast flashing
Fast flashing during start-up
Flashing x 2
Flashing x 3
Slow flashing
Bootloader mode
Calibration
Error During calibration
Fraudulent action.
idle and not enabled (SSP)
Slow flashing
Alternate Flashing
idle and not enabled (CC2)
DES Trusted Channel (CC2 DES enabled)
Slow flashing
Enabled
5.3.1
Table of errors during the sale
LED
N
DESCRIPTION
ACTION
GREEN
1
DEVICE ACTIVE
RED
1
DEVICE DISABLED
Enable the device
RED
2
ERROR DURING CALIBRATION
Contaminated optical sensor.
Clean the optical sensor, if the problem persists, return the
device for assistance
RED
3
THE ENCRYPTION KEY IS NOT
SET
Set the key
RED
4
COIN JAMMED
Turn off the power, remove the coins manually, try turning
the disc to remove the locked coins. If the problem persists,
return the device to service.
RED
5
FRAUD ATTEMPT DETECTED
The photocell on the coin slot has dimmed. Turn the
SAFEMONEY off and on again.
If the problem persists, return the device to service.
RED
6
EMPTY DEVICE, NO MONEY
INSIDE
RED
7
ERROR CHECKSUM
Return the device to service.
RED
8
SENSOR NOT INITIALIZED
Return the device to service.
RED
9
COVER REMOVED
LED STATUS