8
IP2250EN
2. Standard installation
Ref.
Description
Cable
1
Transmitter
/
2
Flashing light
2 x 1 mm²
Antenna (integrated into the flashing light)
coaxial 58 Ω
3
Key selector switch
4 x 0.5 mm²
Digital combination wireless keypad
/
4
Actuator PWR25H
2 x 1.5 mm²
Actuator PWR35H
Actuator PWR35H with magnetic limit switches
3 x 1.5 mm²
5
Photocells
4 x 0.5 mm²
6
Control panel
3G x 1.5 mm²
A
Connect the power supply to a type-approved omnipolar switch, with a contact opening
distance of at least 3mm (not supplied).
The connection to the mains must follow an independent path, separate from the
connections to the control and safety devices.
1
4
6
A
3
2
5
5
4
5