7
IP1982EN
2012-03-22
7. ADJUSTMENTS
Description
OFF
ON
DIP1
Command 1-5 operation.
NOTE: it also sets operating mode of the
plugin cards connected on AUX.
Step-by-step.
Opening.
DIP2
Motor installation position.
The installation position is intended by
viewing the automation from the side be-
ing examined.
Central or right side.
Left side.
DIP3
Restore automatic closing time.
50%
100%
DIP4
Automation status at power on.
Indicates how the control panel considers
automation when powered up.
Open.
NOTE: with limit switches
installed, preferably set
DIP4=OFF.
Closed.
NOTE: if the automatic clos-
ing function is not used,
preferably set DIP4=ON.
DIP5
3 seconds pre
À
ashing.
Disabled during opening.
Enabled only with automatic
closing with TC>3 s.
Enabled for both opening
and closing.
Description
OFF
ON
JR3
Automation type.
2 motors automation.
1 motor automation.
JR4
Incorporated radio receiver.
Disabled.
Enabled.
SO
Reversal safety switch function.
With the automation
bloc
N
ed, if the contact 1-8
is open, it is possible to
activate the opening opera-
tion.
With the automation
bloc
N
ed, if the contact 1-8
is open, any operation is
impossible.
6
Ź
4
Command 1-6 operation.
Closing.
Stop.