DITEC E1HBOX Manual Download Page 7

7

IP1982EN 

‡

 2012-03-22

7. ADJUSTMENTS

Description

OFF

ON

DIP1

Command 1-5 operation.
NOTE: it also sets operating mode of the 
plugin cards connected on AUX.

Step-by-step.

Opening.

DIP2

Motor installation position.

The installation position is intended by 
viewing the automation from the side be-
ing examined.

Central or right side.

Left side.

DIP3

Restore automatic closing time.

50%

100%

DIP4

Automation status at power on.

Indicates how the control panel considers 
automation when powered up.

Open.

NOTE: with limit switches 
installed, preferably set 
DIP4=OFF.

Closed.

NOTE: if the automatic clos-
ing function is not used, 
preferably set DIP4=ON.

DIP5

3 seconds pre

À

ashing.

Disabled during opening.
Enabled only with automatic 
closing with TC>3 s.

Enabled for both opening 
and closing.

Description

OFF 

ON 

JR3

Automation type.

2 motors automation.

1 motor automation.

JR4

Incorporated radio receiver.

Disabled.

Enabled.

SO

Reversal safety switch function.

With the automation 
bloc

N

ed, if the contact 1-8 

is open, it is possible to 
activate the opening opera-
tion.

With the automation 
bloc

N

ed, if the contact 1-8 

is open, any operation is 
impossible.

6

Ź

4

Command 1-6 operation.

Closing.

Stop.

Summary of Contents for E1HBOX

Page 1: ...itecva com Flashing light Step by step Step by step Opening limit switch Closing proximity switch Safety stop Stop Door open indicator light Safety re opening BIXMR2 VA VC TC R1 C NO M M 14 0 1 5 9 13...

Page 2: ...errors ommisions or incomplete data due to technical or illustra tive purposes CAPTION i STOP This symbol indicates instructions or notes regarding safety issues which require particular attention Th...

Page 3: ...the directives in force Good orNing Methods the installation area the functional logic of the system and the forces developed by the automation Before maNing power connections checN that the rating c...

Page 4: ...M M Ma a a a a M M M M Ma a a a ana n na n na n na na na na n na na a a a a n n n n na na na a a a na n n n na a a a a n n na n na na na na a a n n na n na a a a a a a a n n na n na a a a a a na n n n...

Page 5: ...safety contact triggers a reversal of motion re opening during closing 1 9 N C STOP The opening of the safety contact stops the current operation 1 9 N O HOLD TO RUN FUNCTION The opening of the 1 9 co...

Page 6: ...nected AUX The control panel has one housing for plug in cards such as a radio receiver type magnetic loops etc Plug in card operating is selected using DIP1 WARNING the plug in cards must be inserted...

Page 7: ...d up Open NOTE with limit switches installed preferably set DIP4 OFF Closed NOTE if the automatic clos ing function is not used preferably set DIP4 ON DIP5 3 seconds pre ashing Disabled during opening...

Page 8: ...ep opening com mand R1 min max Obstacle thrust adjustment The control panel is equipped with a safety system that stops motion if an obstacle is encountered during an opening operation and inverts the...

Page 9: ...matically exit the procedure 10 s after the last transmission or you can press the PRG button again the SIG LED goes off Up to four CH Neys of a single remote control can be stored if only one any CH...

Page 10: ...safety devices removing the relative jumpers and checN they worN correctly 6 If required adjust the automatic closing time with the TC trimmer WARNING the automatic closing time after a safety device...

Page 11: ...s are clean and operating correctly The automatic closing does not worN ChecN that the TC trimmer is not set at the maximum External safety devices not activating Incorrect connections between the pho...