background image

9

discoverbattery.com

6. System Set Up

6.1 

Synchronizing the Victron System with the AES Battery  

Once the VE.Can and CAN-bus bit rate is set, communication of the AES battery parameters will be automatic. 

During normal operation, the charge parameter limits are set by the BMS of the AES battery and communicated through the system 
by the CCGX to the inverter/charger and MPPT.

To optimize performance of a Victron system the following items need to be manually set using the CCGX.

Navigate from the Device List screen > Settings > System Setup. 

From the System Setup menu scroll down to select each item and then set as indicated. 

• 

Battery Monitor: DISCOVER on CAN-bus

• 

DVCC - Distributed Voltage and Current Control: ON

• 

SVS - Shared voltage sense: OFF 

(7)

• 

STS - Shared temperature sense: OFF

• 

Limit charge current: ON

• 

Max charge current: Installed number of AES batteries x (42-48-6650: 92A < 130A) or (44-24-2800: 78 A < 110 A) 

(8)

(7)  SVS should be set to OFF (there have been instances of conflict reported by Victron Support when SVS is set to ON and used with a Lithium BMS).
(8) Limit charge current works across the whole system. MPPTs are automatically prioritized over the mains. In case the AES BMS requests a maximum charge 
current that is different from the user-configurable setting, the lower of the two will be used.

▲ 

NOTE

• 

To avoid conflicting network information and data, do not 

use a Victron BMV battery monitor when using AES LYNK 

Communication Gateway.

Summary of Contents for LYNK Edge Card Victron

Page 1: ...950 0016 VCTRN LYNK Edge Card Victron User Manual 4 13511 Crestwood Place Richmond BC V6V 2E9 Canada 1 778 776 3288 info discoverbattery com discoverbattery com 805 0020 REV A 5 Installing LYNK and C...

Page 2: ...ified personnel to ensure compliance with applicable installation codes and regulations Failure to follow these instructions can result in death or serious injury CAUTION HAZARD OF EQUIPMENT DAMAGE Do...

Page 3: ...l Discover Reference Documents Discover Energy 808 0004 42 48 6650 Data Sheet Discover Energy 808 0005 44 24 2800 Data Sheet Discover Energy 805 0015 AES LiFePO4 Battery 44 24 2800 42 48 6650 Manual D...

Page 4: ...apacity Battery charge and discharge rates are managed automatically by the AES LiFePO4 Battery and Victron CCGX device Using very large solar arrays with battery banks that are too small can exceed t...

Page 5: ...le Charge curve 2 Select Fixed Select Fixed Absorption voltage 2 27 2 V 54 4 V Float voltage 2 26 8 V 53 6 V Charge current per battery installed Recommended Maximum installed x 78 A 110 A installed x...

Page 6: ...tery voltage 24 V 48 V Max current per battery installed Recommended Maximum 9 installed x 78 A 110 A installed x 92 A 130 A Charger enabled Enabled Enabled Battery preset User Defined User Defined Ab...

Page 7: ...these instructions can damage equipment NOTE Power electronics are not AEBus devices and should not be connected to AEBus 5 3 Connecting LYNK to the Victron Network Before connecting LYNK to the Vict...

Page 8: ...batteries NOTE If Discover does not appear on the Device List confirm that the CAT5 communication cable is a normal patch type and not a cross over type Use manufactured cables to avoid bad crimps and...

Page 9: ...indicated Battery Monitor DISCOVER on CAN bus DVCC DistributedVoltage and Current Control ON SVS Shared voltage sense OFF 7 STS Shared temperature sense OFF Limit charge current ON Max charge current...