3.0 LED INDICATORS

3.1 Normal Operation

Only 1 LED will be on during regular operation. 

Position

Activity

LED 1

Flash - State of Charge 0% to 9 % 
Solid on - State of Charge range 10% to 19 %

LED 2

Solid on - State of Charge range 20% to 29 %

LED 3

Solid on - State of Charge range 30% to 39 %

LED 4

Solid on - State of Charge range 40% to 49 %

LED 5

Solid on - State of Charge range 50% to 59 %

LED 6

Solid on - State of Charge range 60% to 69 %

LED 7

Solid on - State of Charge range 70% to 79 %

LED 8

Solid on - State of Charge range 80% to 89 %

LED 9

Solid on - State of Charge range 90% to 94%

LED 10

Solid on - State of Charge range 95% to 100%

3.2 Charging Operation

The active State of Charge LED will slowly flash

3.3 Battery Protection Indication

When a connected battery has active protection (faults), LED 1  through LED 
10 will all flash at the same time.

3.4 No Battery Detected

The LED interface will continuously cycle through all LEDs when the BDI-B is 
powered on, but no batteries are detected.

Summary of Contents for 950-0034

Page 1: ...TERY DISCHARGE INDICATOR CAN BUS 805 0042 REV A BATTERY MODELS AES LIFEPO4 INDUSTRIAL BATTERIES 12 48 6650 12 36 6700 14 24 2800 14 36 3000 14 48 3000 LITHIUM PROFESSIONAL BATTERIES DLP GC2 12V DLP GC...

Page 2: ...Indication 4 3 4 No Battery Detected 4 4 0 Electrical Overview 5 5 0 Mechanical 5 5 1 Pinout Assignments for BDI 5 6 0 Battery Pinout Assignments 6 6 1 Pinout Assignments for AES LiFePO4 Industrial B...

Page 3: ...ible Batteries AES LiFePO4 Industrial Batteries 12 48 6650 12 36 6700 14 24 2800 14 36 3000 14 48 3000 LITHIUM PROFESSIONAL Batteries DLP GC2 12V DLP GC2 24V DLP GC2 36V DLP GC2 48V 2 0 INSTALLATION O...

Page 4: ...d on State of Charge range 60 to 69 LED 7 Solid on State of Charge range 70 to 79 LED 8 Solid on State of Charge range 80 to 89 LED 9 Solid on State of Charge range 90 to 94 LED 10 Solid on State of C...

Page 5: ...5 4 0 ELECTRICAL OVERVIEW 5 0 MECHANICAL mm 4 3 BATTERY BATTERY DISCHARGE INDICATOR AEBus 12V AEBus CAN High AEBus CAN Low AEBus CAN GND 7 6 2 1 8 5...

Page 6: ...AN 12V Pin 8 LYNK Bus AEBus CAN Low 6 0 BATTERY PINOUT ASSIGNMENTS 6 1 Pinout Assignments for AES LiFePO4 Industrial Batteries IEC M12 A Coding 12 Pin Pin 3 LYNK Bus AEBus CAN GND Pin 4 LYNK Bus AEBus...

Page 7: ...2 LYNK Bus CAN L 3 LYNK Bus CAN H 4 LYNK Bus 12V 5 LYNK Bus GND 7 0 BDI TYPE B ENVIRONMENTAL SPECIFICATIONS Operation 40 C to 85 C 40 F to 185 F Storage 50 C to 90 C 58 F to 194 F Humidity 95 RH non...

Page 8: ...0 INSTALLATION 8 1 Gasket Mounting Front or Back Secure BDI with M 2 5 bolts or screws 8 2 Connect Harness Connect the cable harness to either LYNK Port or AEbus Port on the battery then connect toTY...

Reviews: