- No maintenance or repair work should be carried out on the machine unless it is
disconnected from the mains
fi
rst.
- We recommend every 4-5 years a general check of the electric motor, the bea-
rings, cables including a replacement set of brushes if necessary and a new
fi
lter
should be installed.
6.2 Ordinary maintenance
All these operations are to be carried out on the machine disconnected from the mains
fi
rst and when the cleaner is chilled from the surrounding temperature. This mainte-
nance is made to keep the cleaner working properly and to extend the lifetime of the
cleaner. Disconnect the mains
fi
rst also to clean the cleaner outside and pay attention
that the dust canister is properly
fi
xed on the cleaner’s body.
EMPTYING OF WAST CONTAINER
•
•
1.Unclip the waste unit from the machine
2.Remove the cyclonic separator and
bag support frame
3. Empty the waste container or replace
the plastic bag.
Cod. ER627 x Mod.EVO 200/550
4.Reassemble the cyclonic separator
and the bag support into the waste con-
tainer ensuring all parts are clean and
not damaged.
5. Carefully place the waste container
up to the bottom of the machine in or-
der to make a good seal. (Close both
clamps together)
47