10/100Base-TX Industrial Ethernet Extender 

3

 

Ethernet Extender Mode Settings 

Ethernet Extender mode settings are made very simple by means of a 
switch at the rear panel of the Ethernet Extender. The switch has two 
positions for Ethernet Extender mode settings. Refer to the table below for 
more details. One device must be set to Loc and the other to Rmt when two 
devices are connected. 
 

Loc Rmt 
The device operates in local mode The device operates in remote mode

 

Connecting to Power 

This Ethernet Extender is a plug-and-play device. Connect the supplied AC 
to DC power adaptor to the receptacle on the rear panel of the Ethernet 
Extender, and then attach the plug into a standard AC outlet. 

 

Front Panel & LEDs   

The LED indicators give you instant feedback on status of the Ethernet 
Extender: 
 

LEDs State  Indication 

Steady 

Power on 
Pwr

 

stands for POWER 

Pwr 

Off Power 

off 

Ethernet 

Steady 

A valid Ethernet connection established 
Lnk stands for LINK 

Flashing 

Transmitting or receiving Ethernet data 
Act stands for ACTIVITY 

Lnk/Act 

Off 

Neither valid Ethernet connection established nor transmitting/receiving Ethernet 
data 

Steady  Ethernet Connection transferring at 100Mbps 

100 

Off 

Ethernet Connection transferring at 10Mbps 

Ethernet Extender 

Green 

Link Speed: 1~5Mbps, Distance: 2,600 meters (8,530ft.) 

Amber  Link Speed: 6~10Mbps, Distance: 2,400 meters (7,874ft.) 
Green 

Link Speed: 11~16Mbps, Distance: 2,000 meters (6,561ft.) 

Amber  Link Speed: 17~20Mbps, Distance: 1,800 meters (5,905ft.) 
Green 

Link Speed: 21~29Mbps, Distance: 1,600 meters (5,249ft.) 

Amber  Link Speed: 30~43Mbps, Distance: 1,400 meters (4,593ft.) 
Green 

Link Speed: 44~54Mbps, Distance: 1,200 meters (3,937ft.) 

Amber  Link Speed: 55~63Mbps, Distance: 1,000 meters (3,280ft.) 
Green 

Link Speed: 64~74Mbps, Distance: 600 meters (1,968ft.) 

Amber  Link Speed: 75~85Mbps, Distance: 200 meters (656ft.) 

Rmt 

Steady  The device operates in remote mode 

Loc 

Steady  The device operates in local mode 

Err Steady 

Error 

occurred 

Lnk 

Steady  A valid connection established 

 

Self-diagnostic Test Procedure 

y

  Two Industrial Ethernet Extenders are connected in pairs by BNC 

connectors over coaxial cable. 

Summary of Contents for ED3331

Page 1: ... the Ethernet Extender The Ethernet Extender introduced here provides one channel for Ethernet over existing coaxial cable Product Overview Use DIN Rail Mounting Kit Fit the DIN Rail mounting kit onto the bottom of the unit and fasten the screws The Ethernet Extender can use DIN Rail mounting kit to fix on the DIN Rail ...

Page 2: ...ernet Extender port BNC connector Symmetrical on the VDSL high speed Full duplex 85Mbps communications link over existing coaxial cable y Provides BNC to F Type connector y Supports one DIP switch to select local or remote site y Ten reference speeds supports up to 85Mbps about 200 meters 656ft down to 1Mbps about 2 600 meters 8 530ft y External AC to DC power adapter y 10 to 60 14 to 140 operatin...

Page 3: ...ng Transmitting or receiving Ethernet data Act stands for ACTIVITY Lnk Act Off Neither valid Ethernet connection established nor transmitting receiving Ethernet data Steady Ethernet Connection transferring at 100Mbps 100 Off Ethernet Connection transferring at 10Mbps Ethernet Extender Green Link Speed 1 5Mbps Distance 2 600 meters 8 530ft 1 Amber Link Speed 6 10Mbps Distance 2 400 meters 7 874ft G...

Page 4: ...Rmt remote mode y Connect supplied AC to DC power adaptors to receptacle on rear panel of these two Industrial Ethernet Extenders and then attach plugs into standard AC outlet sockets to power on these two Industrial Ethernet Extenders y LED 5 on top panel of these two Industrial Ethernet Extenders might light on in amber or green color if these two Industrial Ethernet Extenders are connected in p...

Page 5: ... introduced here provides one channel for Ethernet over existing voice grade copper wire The Ethernet Extender fully complies with IEEE802 3 10Base T and IEEE802 3u 100Base TX standards In this manual you will find y Product overview y Features on the Ethernet Extender y Illustrative LED functions y Installation instructions y Specifications ...

Page 6: ...NNECTING TO POWER 3 FRONT PANEL LEDS 3 SELF DIAGNOSTIC TEST PROCEDURE 3 Preface 5 Table of Contents 6 Introduction 7 PRODUCT OVERVIEW 7 PRODUCT FEATURES 7 PACKING LIST 7 One Channel Ethernet Extender 8 PORTS 8 ETHERNET EXTENDER MODE SETTINGS 8 FRONT PANEL LEDS 8 Installation 10 SELECTING A SITE FOR THE EQUIPMENT 10 CONNECTING TO POWER 10 USE DIN RAIL MOUNTING KIT 11 Specifications 12 ...

Page 7: ...ull duplex 85Mbps communications link over existing coaxial cable y Provides BNC to F Type connector y Supports one DIP switch to select local or remote site y Ten reference speeds supports up to 85Mbps about 200 meters 656ft down to 1Mbps about 2 600 meters 8 530ft y External AC to DC power adapter y 10 to 60 14 to 140 operating temperature range y Hardened aluminum case y Supports DIN Rail or Wa...

Page 8: ...rnet Extender Mode Settings Ethernet Extender mode settings are made very simple by means of a 2 position switch at the rear panel of the Ethernet Extender Mode switch There is one position on the Mode switch for Ethernet Extender mode settings Refer to the table below for more details One end must be set to Loc and the other to Rmt when two devices are connected Loc Rmt The device operates in loc...

Page 9: ...5Mbps Distance 2 600 meters 8 530ft 1 Amber Link Speed 6 10Mbps Distance 2 400 meters 7 874ft Green Link Speed 11 16Mbps Distance 2 000 meters 6 561ft 2 Amber Link Speed 17 20Mbps Distance 1 800 meters 5 905ft Green Link Speed 21 29Mbps Distance 1 600 meters 5 249ft 3 Amber Link Speed 30 43Mbps Distance 1 400 meters 4 593ft Green Link Speed 44 54Mbps Distance 1 200 meters 3 937ft 4 Amber Link Spee...

Page 10: ...ature should be between 10 to 60 degrees Celsius y The relative humidity should be less than 95 percent non condensing y Surrounding electrical devices should not exceed the electromagnetic field RFC standards y Make sure that the equipment receives adequate ventilation Do not block the ventilation holes on each side of the equipment y The power outlet should be within 1 8 meters of the product Co...

Page 11: ...X Industrial Ethernet Extender 11 Use DIN Rail Mounting Kit Fit the DIN Rail mounting kit onto the bottom of the unit and fasten the screws The Ethernet Extender can use DIN Rail mounting kit to fix on the DIN Rail ...

Page 12: ...Unit 8 LEDs Pwr Rmt Loc 1 2 3 4 5 LED Indicators Per Port RJ 45 2 LEDs Lnk Act 100 BNC 2 LEDs Err Lnk Dimensions 80 3mm W 109 2mm D 23 8mm H 3 16 W x 4 30 D x 0 94 H Weight 150g 0 33lb Power External power adaptor 12VDC 0 5A Power Consumption 6W Max Operating Temperature 10 C 60 C Storage Temperature 20 C 70 C Humidity 5 95 non condensing Safety UL508 EN60950 1 IEC60950 1 EMI FCC Part 15 Class A E...