Active Ground When Running (Status)
LED
Description
Troubleshooting
Flashes green
Ground When Running (Status) command
received.
The module has initialized the remote start sequence.
Flashes red &
orange
Ignition ON command received.
The module has received the Ignition ON command and is processing the remote start sequence.
Flashes green
quickly
Start ON command received.
The module has received the Start ON command and is processing the remote start sequence.
Flashes red x 10
PTS shutdown error.
The PTS output from the module was not activated due to safety protection.
Flashes red x 21
CAN bus incorrectly detected.
Verify the CAN1 and CAN2 connections. Refer to "Installation (wiring diagrams & vehicle wiring
reference charts)" on page 8 to check the connections.
Commands
LED
Description
Troubleshooting
Flashes orange x 1
LOCK command received.
If the bypass module fails to flash, it did not receive the signal.
Commands can come from RF or D2D.
Flashes orange x 2
UNLOCK command received.
Flashes orange x 3
TRUNK command received.
Flashes orange x 4
AUX1 command received.
Flashes orange x 5
AUX2 command received.
Flashes orange x 6
AUX3 command received.
Shutdown codes
LED
Description
Troubleshooting
Flashes green x 1
Takeover successful.
Normal operation.
Flashes red x 1
Runsafe was not disabled.
No UNLOCK command was received prior to opening the door, or the 45 second timer expired
in takeover mode.
Flashes red x 2
Brake was not detected.
The brakes were not detected, which prevents the system from shutting down the vehicle.
Flashes red x 3
Smart key was not detected.
The smart key was not detected, which prevents the system from shutting down the vehicle.
Flashes red x 4
Speed was detected.
The vehicle was detected as moving, which prevents the system from shutting it down.
Analog error codes
LED
Description
Troubleshooting
Flashes red, green
& orange
DEI feature error.
A feature config file mismatch was detected. Please contact Technical Support.
18
DS4+ FORD11
© 2017-05-08 Directed. All rights reserved.