14
© 2009 Directed Electronics. All rights reserved.
(Blue) wire
Before Unlock: the OEM Alarm Disarm wire will pulse as programmed before the unlock wire
2.
Remote start only: the OEM Alarm Disarm wire will pulse as programmed during remote start only
3.
7. OEM Alarm Disarm Pulses (H2/1 wire)
1: the OEM Alarm Disarm wire will pulse once per operation
1.
2: the OEM Alarm Disarm wire will pulse twice per operation
2.
8. Aux 1 Output Type (H2/6 wire)
Validity: when the Aux command is received the wire will turn on and remain on until the command
1.
ceases
Latch: when the Aux command is received the wire will turn on and remain on until the command is
2.
received again
Latch/reset/Ignition: when the Aux command is received the wire will turn on and remain on until the
3.
command is received again or the ignition is turned on/off
Timed: when the Aux command is received the wire will turn on for the programmed time duration
4.
(default 30sec)
Off: the output will not activate for a remote control command, use this option when the Aux com-
5.
mand controls an external device such as a garage door module
2nd unlock: the wire will operate as 2nd unlock and will not activate for remote control commands
6.
9. Aux 1 Linking
No Linking: the Aux output will not activate for a remote control command
1.
Link to Lock: the Aux output will activate for the Lock command
2.
Link to Unlock: the Aux output will activate for the Unlock command
3.
Link to Lock/Unlock: the Aux output will activate for the Lock & Unlock commands
4.
Link to Remote Start: the Aux output will activate for any Remote Start activation
5.
10. Aux 2 Output Type
Refer to Aux 1 Output Type descriptions
•
11. Aux 2 Linking
Refer to Aux 1 Linking descriptions
•
12. Aux 3 Output Type
Refer to Aux 1 Output Type descriptions
•
13. Aux 3 Linking
Options 1-4: Refer to Aux 1 Linking descriptions
•
Option 5: SmartKey Control (Link to Remote Start Off): The Aux output will pulse once following
•
Remote Start shut down for vehicles with push button engine stop operations. During runtime, if any
door is opened remote start will shut down immediately and pulse the output.
14. Aux 4 Output Type
Refer to Aux 1 Output Type descriptions
•
15. Aux 4 Linking
Refer to Aux 1 Linking descriptions
•
16. Aux/Trunk Output Type
Refer to Aux 1 Output Type descriptions
•