background image

4

Warnings, FCC Compliance Statement 

& Proper Disposal 

Please read and follow all directions and warnings before using this device. 

FCC Compliance Statement

WARNING!

 This equipment generates uses and can radiate radio frequency and if not installed and used in 

accordance with the instruction manual, may cause interference to radio communications. It has been designed 
within the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC rules to provide 
reasonable protection against such interference when operated in a commercial environment. Operation of 
this equipment in a residential area may cause interference in which case the user will be responsible to take 
whatever measures necessary to correct the interference.

You may find the booklet “How to Identify and Resolve Radio TV Interference Problems” prepared by the Federal 
Communications Commission helpful. It is available from the U.S. Government Printing Office, Washington, D.C. 
20402. Request stock No. 001-000-00315-4.

Proper Disposal

When this device reaches the end of its useful life, it must be properly disposed of. It 
must not be disposed of as unsorted municipal waste. The device should be disposed 
of in accordance with the local laws regarding the disposal of waste electrical and 
electronic equipment.

It is everyone’s responsibility to help maintain the environment and to reduce the 
effects of hazardous substances contained in electrical and electronic equipment 
on human health. Please do your part by making certain that this device is properly 
disposed of. The symbol shown above indicates that this device must not be disposed 
of in unsorted municipal waste programs.

• 

CAUTION:

 RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED 

BATTERIES ACCORDING TO THE INSTRUCTIONS.

Warnings

Read and follow all directions and warnings before use or assembly. Do not use or assemble if you do not 
understand the contents of this manual – contact your distributor for assistance. Damage, injury or even death 
may result from improper use of this product or not following directions and warnings. This product is intended 
for use in normal, indoor conditions. This product may not be appropriate for all individuals. 

 

WARNING:

 Prior to use of this product, the user’s medical professional should be consulted to ensure this 

product is appropriate for the user’s specific needs based upon his or her overall medical condition and limitations. 

 

WARNING:

 This product is NOT intended for patient transport. It is to be used ONLY for patient weighing. 

Failure to observe this warning may result in serious injury to the patient and/or the scale operator.

Summary of Contents for Attendant 6880DS

Page 1: ...fully and keep it for future reference This guide will provide you with instructions warnings warranty information and other important information about your Attendant Bluetooth Digital Chair Scale Sh...

Page 2: ...ons 5 Site Preparation Requirements 6 Installation 7 10 Weighing Units Selection 11 Keypad Functions 12 13 Annunciators 14 Operation 15 Setup Calibration 16 23 Data Format 24 Event Counter 25 Printer...

Page 3: ...Calls attention to a potential danger that requires correct procedures or practices in order to prevent personal injury Attention Read the instructions Electrical Shock Hazard Warning PRODUCT or DEVI...

Page 4: ...regarding the disposal of waste electrical and electronic equipment It is everyone s responsibility to help maintain the environment and to reduce the effects of hazardous substances contained in ele...

Page 5: ...SE Capacity 550 x 0 2 lb 250 x 0 1 kg Weighing Height Units Pounds Inch lb in or Kilograms Centimeters kg cm Overall Dimensions Footrest up 373 16 H x 255 8 W x 311 4 D 94 5 cm H x 65 1 cm W x 79 4 cm...

Page 6: ...ng strikes additional protection to minimize lightning damage such as surge suppressors should be installed Electrical Power The Attendant Bluetooth Digital Chair Scale has been designed to operate fr...

Page 7: ...scale and indicator for any damage incurred in shipping If scale or indicator has been damaged DO NOT USE and immediately contact your distributor for further instruction Keep carton and packing mate...

Page 8: ...onic medical record EMR software program The data can be transmitted on demand pressing the key or on receipt of a command from the computer RS232 COM Port The scale has one RS232 serial port on the b...

Page 9: ...RECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THEIR INSTRUCTIONS Battery Status The battery status will be displayed when batteries are installed The battery bar graph on the display indicates the...

Page 10: ...w batteries proceed to step 5 If replacing the batteries remove all 12 batteries 6 in each holder from the battery holders and then proceed to step 5 5 Install the new AA size batteries in the battery...

Page 11: ...s on the weight display will turn on it will change to show the software version for a few seconds and then the display will change to show SEL UNIT with the lb annunciator factory units setting turne...

Page 12: ...to zero This is the Enter key It serves two purposes First during setup pressing the key will accept the current displayed setting of the parameter Second the key is used to signal completion of the e...

Page 13: ...key is used when performing the Body Mass Index BMI calculation to decrease the height value NOTE When entering the height for BMI calculation pressing and holding the up arrow key key allows you to...

Page 14: ...O This annunciator is turned on to indicate that the weight displayed is within 1 4 division of the center of zero LOCK This annunciator is turned on to show that the indicator is locked onto the disp...

Page 15: ...n Note that the amount of time the reading will hold is dependent upon the setting in Setup NOTE If more time is needed press the key to hold the locked weight reading 7 Read and record weight display...

Page 16: ...d calibration While in Setup the current setting prompt will be shown in the smaller upper seven segment display while the value of the current setting will be shown in the large lower seven segment d...

Page 17: ...setting If the value displayed is acceptable press the key Otherwise press the or keys to select a new value and then press the key to save it and proceed to the next prompt This is the number of tim...

Page 18: ...the current setting If the value displayed is acceptable press the key Otherwise press the or keys to select a new value and then press the key to save it and proceed to the next prompt This setting...

Page 19: ...ight on demand and then press the key to save it and proceed to the next prompt This setting controls the output for the USB device port Allowable settings are PHdC ALLYn or SnnA If PHdC Personal Heal...

Page 20: ...ting of the real time clock Allowable values are 1 to 12 1 January 5 May 9 September 2 February 6 June 10 October 3 March 7 July 11 November 4 April 8 August 12 December DAY The display will show dAY...

Page 21: ...HOLD TIME This setting is used by the scale to hold a stable user weight for a desired amount of time For example if a value of 5 seconds is used then when the scale locks onto a stable user weight it...

Page 22: ...eding right a series of dashes will appear on the display The dashes will stay on the display momentarily then disappear after which the calibration factor will be saved and the display will proceed t...

Page 23: ...the CAP prompt the current Scale Capacity setting NOTE If your scale is the model 6880DS equipped with the Redbird Wi Fi and Bluetooth BLE wireless transmitter additional setup prompts will be shown...

Page 24: ...ample and explanation of the data format transmitted is shown below Cont or POLL This format is used if the scale is configured for Cont continuous output OR if the scale is configured for POLL weight...

Page 25: ...t turn on all segments and annunciators and then change to the show the software revision for a few seconds 3 Next the display will change to the Weight Display with the 0 ZERO and STABLE annunciators...

Page 26: ...h day year dd mm yy day month year hh mm hours minutes wwwwww weight uu weight units hhhhh height vv height units bbbb body mass index Print Journal Line Format If 1 Print Journal Line was selected fo...

Page 27: ...made to turn the Bluetooth BLE off when a device is connected to the scale the display will show the error message bLE in the smaller upper seven segment display and E OFF in the large lower seven seg...

Page 28: ...been manually locked by pressing the key This message appears if the key has been pressed without any weight on the scale OCAP The weight on the scale weight exceeds scale capacity ErrOF This message...

Page 29: ...as steel pads and scrapers which will scratch the painted surface Instead use soft cloths or plastic scouring pads for cleaning When possible use treated water Hard water can leave behind deposits Sof...

Page 30: ...nty end once you transfer the device to someone else or at the end of the applicable limited warranty period identified below whichever is earlier Product Part Warranty Period Parts Anticipated Usable...

Page 31: ...31 1 800 245 9917 If you have any questions about the Digital Chair Scale you have purchased or would like to request warranty service please contact your distributor Customer Service...

Page 32: ...5 W Champions Way Milwaukee WI 53223 2020 Direct Supply Manufacturing Inc All Rights Reserved Direct Supply Attendant and all associated logos are the registered trademarks of Direct Supply Inc used u...

Reviews: