24L COMPRESSOR

BP24L20

tank supply tube. When the air pressure in the air
receiver tank reaches the operating pressure of 8
Bar the pressure switch operates and switches OFF
the mains supply to the motor. At the same time
the air that is in the pump cylinder, air receiver
tank, supply tube and the pressure switch is
discharged. This depressurises the pump and the
pressure regulating system allowing the pump to
re-start when the air pressure in the air receiver
tank falls below the minimum operating pressure
of 6 Bar. The pressure switch is fitted with a
delayed discharge valve which will start the air
pump motor. The pressure relief safety valve is set
to operate at 8.5 Bar and is connected directly
onto the air receiver tank and will operate if the
set pressure of 8.5 Bar is exceeded should the
pressure switch fail.

3. OVERLOAD PROTECTION

This compressor is fitted with an overload
protection device, In the event that the motor
becomes too hot a thermal protection device will
cut the mains supply to the motor. When the
motor temperature returns to normal, the mains
supply will be restored automatically. 

4.SWITCHING ON AND OFF

Warning!

Switching ON & OFF must be done

using the ON/OFF switch mounted on the
compressor. Switching the compressor OFF at the
mains supply can damage the motor and will
invalidate the guarantee. 

Before switching on the power supply to the
compressor check that the ON/OFF switch is in the
OFF position (pressed in) (See Fig.5). Check that
the air outlet pressure regulator is closed (See
Fig.6). Check that the water drain cock is closed
(See Fig.7). Connect the compressor to a suitable
13A mains supply. Switch on the compressor by
pulling up the ON/OFF switch (See Fig.8). The
compressor will now start.

Fig 6

Fig 7

Fig 8

Fig 5

Summary of Contents for BP24L20

Page 1: ......

Page 2: ...Full Manufacturer s Warranty 24L COMPRESSOR BP24L20 SAFETY AND OPERATING MANUAL ...

Page 3: ...within the first 12 months you may return the goods for a full refund or we will repair or replace the goods if you prefer When repair is not practical or identical goods are not available alternative goods of similar specification and quality will usually be provided but failing this you will be offered a partial or full refund depending on the time period since purchase This guarantee specifical...

Page 4: ...risk of electric shock d Do not abuse the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock e When operating a power tool outdoors use an extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk of electric shock 3 Pe...

Page 5: ...preventive safety measures reduce the risk of starting the power tool accidentally d Store idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in the hands of untrained users e Maintain power tools Check for misalignment or binding of moving parts breakage of parts and any ot...

Page 6: ...ompressor must be used in a suitable environment There must be adequate ventilation the ambient temperature must be 5 40 C The working area must be free from dust acid vapour explosive gasses and flammable materials 5 Compressed air can be potentially dangerous when not used correctly Do not exceed the maximum rated air pressure for the accessory Do not direct compressed air at yourself any other ...

Page 7: ...24L COMPRESSOR BP24L20 SYMBOLS Read the manual Wear ear protection Warning Caution Hot surface Wear eye and dust protection ...

Page 8: ...ING 4 AIR OUTLET PRESSURE GAUGE 5 AIR OUTPUT QUICK RELEASE CONNECTOR REGULATED 6 AIR OUTPUT QUICK RELEASE CONNECTOR NON REGULATED 7 AIR RECEIVER TANK 8 AIR RECEIVER PRESSURE GAUGE 9 PRESSURE RELIEF SAFETY VALVE 10 AIR PUMP MOTOR 11 WHEELS 12 RUBBER FOOT 13 AIR FILTER 1 2 5 4 3 6 8 9 7 10 13 11 12 ...

Page 9: ...TECHNICAL DATA NOISE DATA 24L COMPRESSOR BP24L20 Voltage 230V 50Hz Input power 2 0HP Receiver capacity 24L CFM 7 66 FAD 90 psi 76L min Maximum pressure 115 psi Net weight 25 kgs As stated on the machine ...

Page 10: ...or spraying paint or spraying cleaning agents the fine mist produced could ignite When performing this type of operation the compressor must be a minimum of 4 Metres away from the work area Do not smoke and keep naked flames and other sources of ignition well away from the work area 2 BASIC COMPRESSOR OPERATION Important Note This manual is provided to allow the correct assembly and basic safe ope...

Page 11: ... 5 Bar is exceeded should the pressure switch fail 3 OVERLOAD PROTECTION This compressor is fitted with an overload protection device In the event that the motor becomes too hot a thermal protection device will cut the mains supply to the motor When the motor temperature returns to normal the mains supply will be restored automatically 4 SWITCHING ON AND OFF Warning Switching ON OFF must be done u...

Page 12: ...release connector See Fig 9 When using the regulated air output first determine the working pressure of the accessory by referring to the accessory manual Slowly open the air outlet pressure regulator See Fig 10 at the same time observing the air outlet pressure gauge until the pressure gauge reads the minimum pressure for the accessory Fine adjustments to the air pressure can be made until the ac...

Page 13: ...ith the air filter removed 3 Cleaning and maintaining the compressor regularly will give a long and trouble free life Before long term storage it is advisable to give the compressor a thorough clean This should include the removal of all fitted accessories Do not use any solvents as these can damage plastic parts Only use a clean cloth dampened with warm soapy water Any metal parts should be given...

Page 14: ...ad are coloured in accordance with the following code Blue Neutral Brown Live Yellow Green Earth The wire that is coloured blue must be connected to the terminal that is marked with the letter N The wire that is coloured brown must be connected to the terminal that is marked with the letter L The wire that is coloured yellow green must be connected to the terminal that is marked with the letter E ...

Page 15: ...24L COMPRESSOR BP24L20 ...

Page 16: ...ctives 89 336 EEC EMC Directive 2006 95 EC Low Voltage Directive 98 37 EEC Machinery Directive 2000 14 EC Noise Directive Standards and technical specifications referred to EN 55014 1 2000 A1 2001 A2 2002 EN 55014 2 1997 A1 2001 EN 61000 3 2 2000 A2 2005 EN 61000 3 3 1995 A1 2001 EN 61000 3 11 2000 2007 Authorised Signatory Date 13 02 07 Signature Name David Withington Nutool Ltd Quality Manager ...

Reviews: