Warnings 

 

1. Do not connect DioLuce LED components to any other 

manufacturers power supply or LED components.  Risk 
of electrical shock or fire.

 

2. Verify incoming voltage matches the voltage rating on 

the power supply, 120 VAC or 277 VAC.

 

3. Do not connect any DioLuce components to fluorescent 

lamp ballast.  Risk of electrical shock or fire.

 

4. Risk of fire or electrical shock.

  

Luminaire wiring and 

electrical parts may be damaged when drilling for 
installation of LED retrofit kit.  Check for enclosed 
wiring and components.

 

5. Risk of fire and electrical shock.  LED Retrofit Kit 

installation requires knowledge of luminaires electrical 
systems.  If not qualified, do not attempt installation.  
Contact a qualified electrician.

 

6. Risk of fire or electrical shock.  Install this kit only in 

luminaires that have the construction features and 
dimensions shown in the drawings and where the input 
rating of the retrofit kit does not exceed the input rating 
of the luminaire.

 

7. To prevent wiring damage or abrasion, do not expose 

wiring to edges of sheet metal or other sharp objects.

 

Summary of Contents for DL-R24-4530-4K0-001

Page 1: ...your local distributor Inspect the components for any damage damage should be reported to your distributor Safety Refer to facility and site safety regulations before performing any work presented in...

Page 2: ...ctrical parts may be damaged when drilling for installation of LED retrofit kit Check for enclosed wiring and components 5 Risk of fire and electrical shock LED Retrofit Kit installation requires know...

Page 3: ...2 SW3 Mode Power Watts Mode Standby 1 0 0 Day Light 40 20 0 1 0 Day Light 35 20 0 0 1 Day Light 30 20 1 1 0 Motion Detector 40 20 0 1 1 Motion Detector 35 20 1 0 1 Motion Detector 30 20 0 0 0 Low 20 1...

Page 4: ...Some components need to be mounted to the existing 4 foot light housing before the fixture can be installed into its operating position 1 To reduce the risk of electrical shock turn off the power at t...

Page 5: ...riate equipment to test the incoming voltage The voltage must be 120 or 277 VAC within the voltage rating shown on the power supply label Turn off all power at the circuit breaker before continuing in...

Page 6: ...ng and tapping screws see warning note 4 7 Connect the incoming power to the power supply according to the electrical connection wiring diagram 8 Peel the double sided tape and mount the side bracket...

Page 7: ...Sensor will be factory mounted in the Functional CDS Sensor Position and connected to the power supply Otherwise it will be shipped loose to be mounted to the inside of the existing housing Connect th...

Page 8: ...DioLuce LLC 185 Main St 4230300 New Britain CT 06051 www dioluce com 8 12 Secure excess wiring and swing the light fixture up into locking position 13 The assembly is complete...

Page 9: ...or equivalent To open the light fixture for service find the labeled side stating OPEN THIS END Insert a rounded blade spatula in between the end bracket and the light fixture at the corner Slide the...

Reviews: