background image

 
 

DioLuce, LLC 185 Main St. #4230300 New Britain, CT 06051 

www.dioluce.com 

1

 

 

Dioluce Products Installation Instructions 

 

 

Models 

DL-R24-4530-5K0-001 
DL-R24-4530-5K0-002 
DL-R24-5035-5K0-001 
DL-R24-5035-5K0-002 
DL-R24-4530-4K0-001 
DL-R24-4530-4K0-002 
DL-R24-5035-4K0-001 
DL-R24-5035-4K0-002 

Important 

 

Read all instructions carefully before attempting installation.  Failure to follow all 
instructions may result in electrical shock, fire and/or injury.  If you do not 
understand these instructions, please contact your local distributor. 

 

Inspect the components for any damage; damage should be reported to your 
distributor. 

Safety 

 

Refer to facility and site safety regulations before performing any work presented 
in this manual to ensure personnel safety. 

 

All electrical connections must be in accordance with the National Electric 
Code and local codes or ordinances. 

 

All work should be performed by a licensed electrician. 

 

This fixture must be mounted into an approved, four foot, recessed light fixture 
that is directly supported by the building structure. 

 

Take note of installation location.  Do not install in a damp, wet location, or next 
to leaking pipes or equipment.  This environment can cause shock or 
electrocution. 

Summary of Contents for DL-R24-4530-4K0-001

Page 1: ...your local distributor Inspect the components for any damage damage should be reported to your distributor Safety Refer to facility and site safety regulations before performing any work presented in...

Page 2: ...ctrical parts may be damaged when drilling for installation of LED retrofit kit Check for enclosed wiring and components 5 Risk of fire and electrical shock LED Retrofit Kit installation requires know...

Page 3: ...2 SW3 Mode Power Watts Mode Standby 1 0 0 Day Light 40 20 0 1 0 Day Light 35 20 0 0 1 Day Light 30 20 1 1 0 Motion Detector 40 20 0 1 1 Motion Detector 35 20 1 0 1 Motion Detector 30 20 0 0 0 Low 20 1...

Page 4: ...Some components need to be mounted to the existing 4 foot light housing before the fixture can be installed into its operating position 1 To reduce the risk of electrical shock turn off the power at t...

Page 5: ...riate equipment to test the incoming voltage The voltage must be 120 or 277 VAC within the voltage rating shown on the power supply label Turn off all power at the circuit breaker before continuing in...

Page 6: ...ng and tapping screws see warning note 4 7 Connect the incoming power to the power supply according to the electrical connection wiring diagram 8 Peel the double sided tape and mount the side bracket...

Page 7: ...Sensor will be factory mounted in the Functional CDS Sensor Position and connected to the power supply Otherwise it will be shipped loose to be mounted to the inside of the existing housing Connect th...

Page 8: ...DioLuce LLC 185 Main St 4230300 New Britain CT 06051 www dioluce com 8 12 Secure excess wiring and swing the light fixture up into locking position 13 The assembly is complete...

Page 9: ...or equivalent To open the light fixture for service find the labeled side stating OPEN THIS END Insert a rounded blade spatula in between the end bracket and the light fixture at the corner Slide the...