INSTALLATION GUIDE

Wire 

Gauge

10 W

.42 A

20 W

.83 A

30 W

1.3 A

40 W

1.7 A

50 W

2.1 A

60 W

2.5 A

18 AWG

134 ft.

68 ft.

45 ft.

33 ft.

27 ft. 

22 ft. 

16 AWG

215 ft.

109 ft.

72 ft.

54 ft.

43 ft.

36 ft.

14 AWG

345 ft. 

174 ft.

115 ft.

86 ft. 

69 ft.

57 ft.

12 AWG

539 ft.

272 ft.

181 ft.

135 ft.

108 ft. 

90 ft.

10 AWG

784 ft.

397 ft.

263 ft.

197 ft.

158 ft.

131 ft.

INSTALLATION (676) (CONT.)

Wire 

Gauge

10 W

.42 A

20 W

.83 A

30 W

1.3 A

40 W

1.7 A

50 W

2.1 A

60 W

2.5 A

70 W

2.9 A

80 W

3.3 A

100 W

4. 2 A

18 AWG

134 ft.

68 ft.

45 ft.

33 ft.

27 ft. 

22 ft. 

19 ft.

17 ft.

14 ft.

16 AWG

215 ft.

109 ft.

72 ft.

54 ft.

43 ft.

36 ft.

31 ft.

27 ft.

22 ft.

14 AWG

345 ft. 

174 ft.

115 ft.

86 ft. 

69 ft.

57 ft.

49 ft.

43 ft. 

36 ft.

12 AWG

539 ft.

272 ft.

181 ft.

135 ft.

108 ft. 

90 ft.

77 ft.

68 ft.

56 ft.

10 AWG

784 ft.

397 ft.

263 ft.

197 ft.

158 ft.

131 ft.

112 ft.

98 ft.

82 ft.

24V Voltage Drop & Wire Length Distance Chart

Example: 24V Voltage Drop & Wire Length Distance Chart 

Determine load size. Let’s assume 

load is 55 W. Round up to nearest 

load.

1

Determine distance from driver 

to load. Let’s assume the 

distance is 90 ft.

2

It is recommended to install 12 AWG to 

eliminate excess voltage drop.

3

VOLTAGE DROP CHARTS

For best performance and lumen output, ensure proper wire gauge is installed to compensate for voltage drop of low voltage circuits. 

4

5

6

ATTACH CONTROL AND DRIVER

Verify  a  compatible  constant  voltage  driver  is  installed.  Utilize 

applicable wiring when installing outdoors.

REVIEW SYSTEM

Ensure all polarities are correct and connections are secured.

TURN POWER ON AT CIRCUIT BREAKER

Shift in 

brightness 

and/or kelvin

•  Ensure an appropriate gauge of 

wire is installed between strip light 

and LED driver. 

See VOLTAGE 

DROP CHARTS.

Some LEDs 

are not 

functional

•  Ensure strip light has not been bent 

excessively,  which  could  damage 

circuitry.

Lights are 

flickering

•  Ensure a compatible driver and/or 

dimming control is installed. Check 

for loose connections.

Lights are 

turning on/off 

repeatedly

•  Ensure driver is not overloaded. An 

overloaded driver will trip the internal 

auto-reset  (of  driver)  repeatedly, 

turning the system on/off.

TROUBLESHOOTING

Summary of Contents for Hydrolume

Page 1: ...and may shift in color and other properties after product installation particularly with direct exposure to sun chlorinated water and other chemicals 5 Only install with a Listed Class 2 DC LED driver...

Page 2: ...n driver fixture and any controls in between When choosing wire factor in voltage drop amperage rating and type in wall rated wet location rated etc For more information refer to system diagrams and v...

Page 3: ...W D1 D2 D2 MASTER SLAVE REQUIRED COMPONENTS 1 2 3 4 5 REQUIRED TOOLS 1 2 3 4 1 Appropriate Junction Box 2 Class 2 rated Driver 3 Color Controller 4 HYDROLUME SLIM RGB LED Strip Light 5 HYDROLUME SLIM...

Page 4: ...other HYDROLUME SLIM MOUNTING CHANNEL ATTACH CONTROL AND DRIVER Ensure all polarities are correct and connections are secure TURN POWER ON AT CIRCUIT BREAKER a b INSTALLATION 2108 CONT Verify compatib...

Page 5: ...ost fiberglass and vinyl lined pools have strict warranty guidelines that do not allow the user to deface the pool wall surface Diode LED does not recommend mounting to fiberglass or vinyl pool walls...

Page 6: ...e Chart Determine load size Let s assume load is 55 W Round up to nearest load 1 Determine distance from driver to load Let s assume the distance is 90 ft 2 It is recommended to install 12 AWG to elim...

Page 7: ...wire gauge type AC Power 50 60Hz L N Class 2 Low Voltage Driver3 Installed in Junction Box G N L V V V V RGB RGBW Controller V W B G R RGBW Strip Light Fixture 8 INPUT OUTPUT V V V CH1 R CH2 G CH3 B...

Reviews: