4 OF 5
IG050421-2.0
DMX ZONE CONTROLLER
INSTALLATION GUIDE
SYSTEM DIAGRAM
The following diagram is provided as an example system design. CAT5 (RJ45 connections) data cables are the most cost-effective solution for
transmitting DMX-512 signals. XLR-3 cables may also be installed but require an additional adapter for connecting to DMX decoders. Always review
each component installation guide for detailed and up-to-date wiring instructions. Install in accordance with NEC and local regulations.
V+
V-
V+
CH1 - R
CH2 - G
CH3 - B
CH4 - W
0-5 0-9 0-9
Data IN
Data OUT
V+
V-
V+
CH1 - R
CH2 - G
CH3 - B
CH4 - W
0-5 0-9 0-9
Data IN
Data OUT
G
+
-
DMX Data
Output
Power
Input
AC Power
50/60Hz
L
N
Class 2 Low Voltage Driver
Installed in Junction Box
G*
N
L
Input
Output
V+
V-
DMX Controller
Installed in Wall Box
CAT5 / Ethernet Cable (RJ45 Connections)
DMX Decoder
DMX Decoder
V- V+
V- V+
RJ45 Coupler
RJ45 Splice Cable
V+ V+
CH1 WW
CH2 CW
Install applicable wire gauge / type
Blaze™ Select LED Tape Light
V+ V+
CH1 WW
CH2 CW
Blaze™ Select LED Tape Light
RJ45 Splice Cable
Wiring Connections
Brown Ground
White/Orange Data +
Orange Data -
White/Brown wire may be used as
an additional ground.
S1
S2
S3
AC Power
50/60Hz
L
N
Class 2 Low Voltage Driver
Installed in Junction Box
G*
N
L
Input
Output
V+
V-