DWG2000 GSM/CDMA/WCDMA User
Manual
11
Copyright @ 2015
3
Basic Operation
3.1
Feature Codes
Users can do some basic system setting via dialing feature codes through a telephone.
The DWG2000 has a built-in IVR navigator for local maintenance. In each step, if you hear an IVR message
of “setting succeeds”, it means you have finished this step successfully. However, if you hear “setting fails”,
please check and redo that step.
Code
Corresponding Function
*150*
Dial *150*1 to set the IP address of the
gateway
as static IP address; dial *150*2 to set the IP address
as DHCP IP address
*152*
Dial *152*192*168*1*10# to set the IP address of
the
DWG2000 device as 192.168.1.10.
( 192.168.1.10 is just an example)
*156*
Dial *156*192*168*1*1# to set the default gateway of the network as 192.168.1.1.
( 192.168.1.1 is just an example)
*153*
Dial *153*255*255*0*0*# to set the netmask of the network as 255.255.0.0
(255.255.0.0 is just an example)
*158#
Dial *158 to inquiry IP address of the device
*111#
Dial *111# to restart the device
3.2
Basic Operation
3.2.1
Check IP address
Use a mobile phone to call a SIM card number of the
DWG2000 device
, then the device will answer and play
a voice prompt of ‘dial the extension number’. Press *158# on mobile phone, then the device will report its
local IP address automatically.
3.2.2
Restore factory setting via IVR
Use a mobile phone to call a SIM card number of the
DWG2000 device
, the device will answer and play a
voice prompt of ‘dial the extension number’. Press *166*000000# on the mobile phone, then you will hear
‘setting succeeds’, then the factory setting of the gateway will be restored.
3.2.3
Restore default IP and password
Press RST button for about 3 seconds, then the device will be rebooted and the IP address, username and
password will be restored to factory default.