35
▪
ERROR DESCRIPTION display
▪
ERROR CONDITION display
Error condition
Error code
Error description and possible diagnosis
AUT
ADJ
POWER LIMITATION
This alarm appears if the power limit is exceeded. The alarm alternates with the
standard display every 1.5 seconds, despite which the machine continues to weld,
supplying limited power, but complying with the values shown on the data plate.
Err
T°C
THERMAL PROTECTION
The welding stops due to an excessively high temperature (thermostat activated).
Automatic reset error.
Err
H20
COOLER PRESSURE
The fluid in the cooling system is at low pressure.
NON automatic reset error.
Err
E0.0
POWER SUPPLY FAILURE
NON automatic reset error
.
This error can only arise when switching on and not when the welding equipment is
working normally.
Err
E0.1
OVER AND UNDER VOLTAGE
Automatic reset error.
Err
E0.2
OVER VOLTAGE
Automatic reset error.
Err
E0.3
UNDER VOLTAGE
Automatic reset error.
Err
E0.4
OVER CURRENT
Automatic reset error.
Err
E1.0
CONFIG. FILE MISSING
NON automatic reset error. Immediately contact technical assistance dept.
Err
E1.1
USER FILE MISSING
NON automatic reset error. Immediately contact technical assistance dept.
Err
E1.3
CALIBRATION FILE MISSING
NON automatic reset error. Immediately contact technical assistance dept.
Err
E1.6
MMA DEFAULTS MISSING
NON automatic reset error. Immediately contact technical assistance dept.
Err
E1.7
DEFAULTS MISSING TIG
NON automatic reset error. Immediately contact technical assistance dept.
Err
E1.8
DEFAULTS MISSING MIG
NON automatic reset error. Immediately contact technical assistance dept.
Err
E1.9
WELDER DEFAULTS MISSING
NON automatic reset error. Immediately contact technical assistance dept.
Err
E2.0
FILE SYSTEM ERROR
NON automatic reset error. Immediately contact technical assistance dept.
Err
E3.2
STICKING
This error is displayed when a shortcircuit has been formed between the machine’s
output terminals for more than 1.2 seconds.
NON automatic reset error.
To remove the error state, eliminate the short circuit so that the voltage on the torch
goes above the threshold value again. At this stage the error condition disappears and
the welding machine goes back to the mode prior to the sticking. If the torch trigger is
still pushed, it must be released and pressed again to begin welding again.
Err
E4.0
LAST SETUP NOT VALID
NON automatic reset error. Immediately contact technical assistance dept.
Err
E4.1
JOBS WRONG
NON automatic reset error. Immediately contact technical assistance dept.
(continued)