39
• Control Panel
Standby current: 20mA
Alarm current: ≤ 500mA
Power supply: 12V DC
Working temperature: -10°C ~ +85°C
GSM frequency : 850/900/1800/1900MHz quad band Receiv-
ing code: ASK
Transmission Frequency ( RF): 315/433MHZ±0.5MHZ Trans-
mission distance: 100 M
wireless detectors: 99
wire detectors: 7
• Door Contact
Power Supply: DC12V (inner 12V battery) Standby Current: ≤
20 uA
Transmission Current: ≤ 15mA
Transmission Frequency: 315/433MHZ±0.5MHZ Transmis-
sion Distance: No obstacle 80m Internal Distance: 15 mm
Working Condition: Temperature –10°C ~+ 40 °C Humidity:
≤ 90% rh
• PIR Detector
Power Supply: DC9V (inner 9V battery)
Standby Current: ≤ 100 uA
Transmission Current: ≤ 20mA
Transmission Frequency: 315/433MHZ±0.5MHZ Transmission Distance:
No obstacle 80m Detective Speed: 0.3 - 3m/s
Detective Distance: 5 - 12m
Detective Range: Horizontal 110° Vertical 60°
Working Condition: Temperature –10 °C ~+ 40 °C
Humidity: ≤ 90 rh
• Remote Controls
Power Supply: DC=12V~8.4(Inside A23 DC=12V dry battery) Standby
Current: 0
Transmission Current: ≤ 15 mA
Transmission Frequency: f=433.92±0.2 MHz
Transmission Speed: T ≤ 1 second
Transmission Distance: Without obstacle 80m
Working Condition: Temperature -10°C~ +40°C
Humidity: ≤ 90 rh
Appendix I: Technical Parameters
Summary of Contents for MatiGard
Page 1: ...MatiGard User Guide...
Page 2: ...02...
Page 4: ...04...
Page 9: ...09 Overviews A1 A0 A2 Image 3 Wired Sensor Wired Sensor External Plug in Board...
Page 20: ...20 image4 Auth Code Login UsingMagictrl...
Page 36: ...36 Installing UsingTheAccessories PIR Sensor Installation 10 30o 8 12m 2 2m 110o...
Page 41: ......