51
The emergency descent system can also be used for raising the stabilisers to the transport
position:
• Start the emergency descent unit from the UCB control panel
• Lift the stabilisers
Setup of the system
• battery 12V 68Ah
• hydraulic unit 12 VDC
• (automatic charger of the battery 12VDC 10A, on the model powered by electric motor )
The hydraulic unit comprises:
• pressure relief valve, set value 21 MPa (210 bar)
• check valve
• direct current motor
• hydraulic pump
Always check the condition of the emergency descent system before
starting to use the lift.
5.3.3. In case the emergency descent battery is empty
In case of a malfunction where even the emergency descent system does not operate, try to
warn other personnel present on the site so that they can help or call for more help.
When help arrives, they should try to:
• restore the power supply required for normal operation
• make the emergency descent system operational by, for example, changing the battery
so that the person on the platform can be lowered safely.
• resume normal operation by other means
Do not use the lift until the fault is repaired!