8
Optimized layout for A4 print.
USER_MAN_ENG_DGT1SP
Transmitter installation
Installation requirements
Observe the following conditions for correct installation of the transmitter and of the load receiver:
•
Flat, level support surface.
•
Stability and absence of vibrations.
•
Absence of aggressive dusts and vapours.
•
Absence of draughts.
•
Make sure that the platform is levelled or that the load cells are evenly supported.
•
Moderate temperature and humidity (15°C - 30°C and 40% - 70%).
•
Do not install in an environment where there is a risk of explosion.
•
All transmitter connections must be made in accordance with applicable regulations in the area and environment of installation.
Observe the electrical precautions listed in the section “
•
Ensure that it is correctly earthed, see the relevant section “
•
Do not perform welding when the load cells have already been installed.
•
If necessary, use watertight sheaths and fittings to protect the load cell cables.
•
Any junction boxes must be watertight.
•
Anything not expressly described in this manual constitutes improper use of the equipment.
Summary of Contents for DGT1SP
Page 1: ...www diniargeo com DGT1SP Digital weight transmitter ENGLISH USER MANUAL...
Page 2: ......
Page 6: ...6 Optimized layout for A4 print USER_MAN_ENG_DGT1SP...
Page 57: ...57 Optimized layout for A4 print USER_MAN_ENG_DGT1SP Notes...
Page 58: ...58 Optimized layout for A4 print USER_MAN_ENG_DGT1SP Notes...
Page 59: ......