Beijing Dingtek Technology Corp., Ltd.
Tel:86-10-64718863, 64753700
E-mail: [email protected]
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022
Page 5
Data Time Intervals
For example Test time data every 10 minutes, when a change of state is detected the data
will be upload, the state remains unchanged in next intervals, and no data will be uploaded.
The data will be uploaded periodically like as heartbeat the data interval default 4 hours can
be modified, specific reference to the agreement.
State change means:
From full to not from
Not from to full
Main
Function
Functional
Descriptio
n
Default Alarm
Threshold
Whether the
data will be
reported
immediately
when
the
alarm
condition is
reached
Remarks
Full
Check if the
Trash bin is
full
30cm
(Can
be
modified)
No
The Device will detect
the Distance between
sensor and garbage if
this Distance is more
Then 30cm no alarm
if less than 30 cm
alarm
will
be
activated.
Fire
Detect if a
fire
has
been
occurred
75
℃
(Can
be
modified above
75
℃
Fire alarm will
be activated )
Yes
Detected temperature
is less than 75
℃
above
this
Temperature sensor
will
activate
the
alarm.
Fall
Check
whether the
trash
Bin
can
fallen
any side
This
feature
is
available in enhanced
version
not
in
slandered version.
Battery
Check if the
battery
is
about to run
out
20%
(Can
be
modified)
No
It will detect the
power
of
battery
more than 20% no
alarm less than 20%
alarm
will
be
activated.